DESIGN AND OPERATING PRINCIPLE

Filters

Clean the air stream of dust and 
foreign objects and prevent 
contamination of the 
regenerator.

Front part of the indoor unit with front panel

For decoration purpose and closing of the air duct at the 
standstill of the ventilator. The front part of the Vento 
Expert Duo also provides air filtration.

Indoor unit rear part

The unit includes a circuit control board and basic controls on the side part.

Indoor unit rear part

The unit includes a circuit control board and 

basic controls on the side part.

Vento Expert Duo cartridge

Assembly unit consisting of fans and a regenerator.
Generates air flow and provides energy regeneration.

Vento Expert

 cartridge

Assembly unit consisting of fans, a regenerator and air filters. 

Generates air flow and provides energy regeneration.

Air duct

Plastic air duct.

Air flow separators

Designed for separation of 
supply and exhaust air streams.

Outer ventilation hood

Protects the unit from ingress of water and foreign objects.

Each ventilator model has a matching ventilation hood model.

Sound absorbing mat

Sound insulating material that provides attenuation of operation noises.

Vento Expert Duo

Vento Expert

FUNCTIONING OF THE AIR SHUTTERS FOR Vento Expert

Shutters are closed

Shutters are open

The ventilator consists of an indoor unit with a decorative front panel, a cartridge, an air duct with a sound absorbing mat and an outer 
ventilation hood.
Cartridge is the basic functioning part of the ventilator. The cartridge consists of fans, a regenerator and two filters that ensure rough air 
filtration and prevent ingress of dust and foreign objects into the regenerator and the fan.
The indoor unit is equipped with an automatic air shutters that close during power-off of the ventilator and prevents air backdraft.

Vento Expert Duo

 is equipped with a set of air flow separators. The design of the supplied ventilation hood ensures opposite direction 

of extract and supply air flows.
The ventilation hood must be installed on the outer wall to prevent ingress of water and foreign objects into the unit.

The indoor unit is equipped with an automatic air shutters. During operation of the ventilator the air shutters open to let air flow through 
the ventilator. After the unit shutdown the shutters close within 2 minutes.

Summary of Contents for Vento Expert A100-1 W V.2

Page 1: ...Single room reversible energy regeneration ventilator USER S MANUAL EN Vento Expert A50 1 W V 2 Vento Expert A85 1 W V 2 Vento Expert A100 1 W V 2 Vento Expert Duo A30 1 W V 2...

Page 2: ...ics design or configuration of its products at any time in order to incorporate the latest technological developments No part of this publication may be reproduced stored in a retrieval system or tran...

Page 3: ...r Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any exp...

Page 4: ...le or explosive mixtures evaporation of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic subs...

Page 5: ...ous parts access and water ingress protection rating is IP24 The unit design is constantly being improved so some models may be slightly different from those ones described in this manual Technical da...

Page 6: ...a matching ventilation hood model Sound absorbing mat Sound insulating material that provides attenuation of operation noises Vento Expert Duo Vento Expert FUNCTIONING OF THE AIR SHUTTERS FOR Vento E...

Page 7: ...ed in the regenerator In 70 seconds after the regenerator cools down the ventilator goes again to the extract mode and the cycle starts from the beginning In this mode in case of installation of two v...

Page 8: ...e air duct in the wall hole For ease of installation use the polystyrene wedges included in the delivery set The air duct end must protrude for the distance A that enables installation of the outer ve...

Page 9: ...bs to detach the front part of the indoor unit from its rear part ATTENTION Prior to mounting the front panel make sure that the thermal actuator rod is in the lowest position Blinking of the white LE...

Page 10: ...tecting paper layer outside Insert the roll in the air duct against stop to the cartridge Make a mark at the end of the air duct remove the sound absorbing mat and cut the roll according to the markin...

Page 11: ...e signal cables The above wire cross section value is tentative The signal cable must be shielded The actual conductor cross section selection must be based on the wire type maximum wire temperature i...

Page 12: ...unit 1 ON Slave unit Standby mode setup 2 OFF the ventilator is off in the Standby mode 2 ON the ventilator is running at the first speed in the Standby mode SetupofairflowdirectioninVentilationmodewi...

Page 13: ...tilation indicates forced activation of the supply ventilation mode of the ventilator This mode may be activated via the mobile application only Filter The filter clogging indicator starts blinking 90...

Page 14: ...tion mode Ventilation mode Vento Expert The ventilator runs in the extract or in the supply mode at the set speed The fan rotation direction depends on the position of the DIP switch 3 Vento Expert Du...

Page 15: ...mobile device to the Wi Fi access point with the name FAN 16 ID Number characters stated on the ventilator casing under the front panel Wi Fi access point password 11111111 1 2 4 5 6 8 7 3 Enter the B...

Page 16: ...the ventilator operation mode 4 hours by default adjustable in the menu Settings Timers DESCRIPTION OF MOBILE APPLICATION INDICATORS Current type of connection to the ventilator Home connection or co...

Page 17: ...n below the set point the turn off delay timer for the Boost mode is activated After the delay timer countdown the ventilator reverts to the previous speed setting Sensor 0 10 V actuation of the analo...

Page 18: ...he date and time The ventilator filters must be serviced after every 90 hours of continuous operation The need to replace the filters is communicated by the indicator in the upper section of the Contr...

Page 19: ...the same speed In case of actuation of any sensors for Vento Expert Duo only the affected ventilator goes to the maximum speed according to the humidity control scenario The rest of the ventilators c...

Page 20: ...the Master unit with its own wireless access point In case of connection of eight Slave units to the Master unit with its own wireless access point a mobile device may not be connected Wiring diagram...

Page 21: ...access to the ventilator functions To enter the special setup mode press and hold the Ventilation button on the ventilator casing for 5 seconds until the beep and blinking of all the LED lights The ve...

Page 22: ...ny loss of Internet connection provided by the home server may result in temporary loss of communication with the ventilator Create a new account for control of the Master ventilator For that open the...

Page 23: ...ndicator glowing goes down AIR FLOW BLOCKING FOR Vento Expert Duo Press the side tabs to detach the front part of the indoor unit from its back part and close the air duct Then open the latches and re...

Page 24: ...il it goes down up to 2 minutes Warning Prior to mounting the front panel make sure that the ther mal rod is in the low position and the indicator of the circuit board glows Vento Expert Duo 1 Press t...

Page 25: ...ular technical maintenance may not completely prevent dirt accumulation on the regenerator and the fans Clean the regenerator regularly to ensure its high regeneration efficiency Clean the regenerator...

Page 26: ...ler is contaminated Clean the impeller Loose screw connection in the ventilator casing or in the outer ventilation hood Tighten the screws of the ventilator or the outer ventilation hood Store the uni...

Page 27: ...manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing compon...

Page 28: ...www blaubergventilatoren de Vento Expert Duo A W V 2 28...

Page 29: ...www blaubergventilatoren de Vento Expert Duo A W V 2 29...

Page 30: ...www blaubergventilatoren de Vento Expert Duo A W V 2 30...

Page 31: ...e of the complete unit delivery with the user s manual The warranty terms are acknowledged and accepted Customer s Signature The Vento Expert _________________ unit has been connected to power mains p...

Page 32: ...www blaubergventilatoren de B133 4EN 04...

Reviews: