background image

www.blaubergventilatoren.de

vento expert (Duo) a W v.2

17

VENTILATOR PASSWORD CHANGE

TIMER SETUP

SENSOR SETUP

To change the ventilator password in the mobile application go to 

Menu - 

Connection - Home

.

1. Select the connection type and press the Settings button.
2. Enter and confirm the password.
3. Press the 

Change Password

 button.

1

2

3

To set the 

"Night mode"

,

 "Party mode"

 timer and the turn-off delay timer for the 

"Boost"

 mode, go to 

Menu - Settings - Timers

 in the mobile application. 

The 

"Night mode"

 timer sets transition time to the low speed after activation of the Night mode (8 hours 

by default).
The 

“Party”

 timer sets transition time to the high speed after activation of the Party mode (4 hours by 

default).
The 

turn-off delay timer for the "Boost"

 mode defines switch delay to the high speed after actuation of 

any sensor and reset of the sensor to the standard status.

To set up sensor operation via the mobile application go to 

Menu - Settings -Sensors

.

Humidity sensor:

 actuation of the humidity sensor. When the indoor humidity exceeds the set point, 

the ventilator goes to the third speed. When the indoor humidity drops down below the set point, the 
turn-off delay timer for the "Boost" mode is activated. After the delay timer countdown, the ventilator 
reverts to the previous speed setting. Sensor 0-10 V: actuation of the analogue 0-10V sensor. If the 0-10 
V control signal exceeds the set value, the ventilator goes to the maximum speed. After decrease below 
the set value the Boost delay timer is activated. After its operation is completed the ventilator reverts to 
the previous speed. 

Relay sensor:

 actuation of the external relay sensor. As the NO contact of the external relay sensor 

is closed, the ventilator goes to the high speed. As the NO contact opens, the turn-off delay timer for 
the "Boost" mode is activated. After the ventilator operation in the Boost mode comes to the end, the 
ventilator reverts to the previous speed setting.

Note:

 for activation/deactivation of the sensors and setup of the sensor threshold points for 

Vento Expert Duo ventilators in the Slave mode follow the steps:
• 

turn the ventilator to the Master mode using the DIP switch No. 1 (refer to page 13)

• 

set the ventilator into the special setup mode (refer to page 22)

• 

connect to the unit via a mobile device (refer to page 16)

• 

set the sensors using the mobile application

• 

exit the special setup mode

• 

turn the ventilator to the Slave mode using the DIP switch No. 1

Summary of Contents for Vento Expert A100-1 W V.2

Page 1: ...Single room reversible energy regeneration ventilator USER S MANUAL EN Vento Expert A50 1 W V 2 Vento Expert A85 1 W V 2 Vento Expert A100 1 W V 2 Vento Expert Duo A30 1 W V 2...

Page 2: ...ics design or configuration of its products at any time in order to incorporate the latest technological developments No part of this publication may be reproduced stored in a retrieval system or tran...

Page 3: ...r Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any exp...

Page 4: ...le or explosive mixtures evaporation of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic subs...

Page 5: ...ous parts access and water ingress protection rating is IP24 The unit design is constantly being improved so some models may be slightly different from those ones described in this manual Technical da...

Page 6: ...a matching ventilation hood model Sound absorbing mat Sound insulating material that provides attenuation of operation noises Vento Expert Duo Vento Expert FUNCTIONING OF THE AIR SHUTTERS FOR Vento E...

Page 7: ...ed in the regenerator In 70 seconds after the regenerator cools down the ventilator goes again to the extract mode and the cycle starts from the beginning In this mode in case of installation of two v...

Page 8: ...e air duct in the wall hole For ease of installation use the polystyrene wedges included in the delivery set The air duct end must protrude for the distance A that enables installation of the outer ve...

Page 9: ...bs to detach the front part of the indoor unit from its rear part ATTENTION Prior to mounting the front panel make sure that the thermal actuator rod is in the lowest position Blinking of the white LE...

Page 10: ...tecting paper layer outside Insert the roll in the air duct against stop to the cartridge Make a mark at the end of the air duct remove the sound absorbing mat and cut the roll according to the markin...

Page 11: ...e signal cables The above wire cross section value is tentative The signal cable must be shielded The actual conductor cross section selection must be based on the wire type maximum wire temperature i...

Page 12: ...unit 1 ON Slave unit Standby mode setup 2 OFF the ventilator is off in the Standby mode 2 ON the ventilator is running at the first speed in the Standby mode SetupofairflowdirectioninVentilationmodewi...

Page 13: ...tilation indicates forced activation of the supply ventilation mode of the ventilator This mode may be activated via the mobile application only Filter The filter clogging indicator starts blinking 90...

Page 14: ...tion mode Ventilation mode Vento Expert The ventilator runs in the extract or in the supply mode at the set speed The fan rotation direction depends on the position of the DIP switch 3 Vento Expert Du...

Page 15: ...mobile device to the Wi Fi access point with the name FAN 16 ID Number characters stated on the ventilator casing under the front panel Wi Fi access point password 11111111 1 2 4 5 6 8 7 3 Enter the B...

Page 16: ...the ventilator operation mode 4 hours by default adjustable in the menu Settings Timers DESCRIPTION OF MOBILE APPLICATION INDICATORS Current type of connection to the ventilator Home connection or co...

Page 17: ...n below the set point the turn off delay timer for the Boost mode is activated After the delay timer countdown the ventilator reverts to the previous speed setting Sensor 0 10 V actuation of the analo...

Page 18: ...he date and time The ventilator filters must be serviced after every 90 hours of continuous operation The need to replace the filters is communicated by the indicator in the upper section of the Contr...

Page 19: ...the same speed In case of actuation of any sensors for Vento Expert Duo only the affected ventilator goes to the maximum speed according to the humidity control scenario The rest of the ventilators c...

Page 20: ...the Master unit with its own wireless access point In case of connection of eight Slave units to the Master unit with its own wireless access point a mobile device may not be connected Wiring diagram...

Page 21: ...access to the ventilator functions To enter the special setup mode press and hold the Ventilation button on the ventilator casing for 5 seconds until the beep and blinking of all the LED lights The ve...

Page 22: ...ny loss of Internet connection provided by the home server may result in temporary loss of communication with the ventilator Create a new account for control of the Master ventilator For that open the...

Page 23: ...ndicator glowing goes down AIR FLOW BLOCKING FOR Vento Expert Duo Press the side tabs to detach the front part of the indoor unit from its back part and close the air duct Then open the latches and re...

Page 24: ...il it goes down up to 2 minutes Warning Prior to mounting the front panel make sure that the ther mal rod is in the low position and the indicator of the circuit board glows Vento Expert Duo 1 Press t...

Page 25: ...ular technical maintenance may not completely prevent dirt accumulation on the regenerator and the fans Clean the regenerator regularly to ensure its high regeneration efficiency Clean the regenerator...

Page 26: ...ler is contaminated Clean the impeller Loose screw connection in the ventilator casing or in the outer ventilation hood Tighten the screws of the ventilator or the outer ventilation hood Store the uni...

Page 27: ...manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing compon...

Page 28: ...www blaubergventilatoren de Vento Expert Duo A W V 2 28...

Page 29: ...www blaubergventilatoren de Vento Expert Duo A W V 2 29...

Page 30: ...www blaubergventilatoren de Vento Expert Duo A W V 2 30...

Page 31: ...e of the complete unit delivery with the user s manual The warranty terms are acknowledged and accepted Customer s Signature The Vento Expert _________________ unit has been connected to power mains p...

Page 32: ...www blaubergventilatoren de B133 4EN 04...

Reviews: