DESCRIPTION OF MOBILE APPLICATION CONTROL BUTTONS
ON/Standby. The
Standby
mode is determined by the DIP switch No. 2
position (see page 12).
Selection of the pre-set speed: first, seconds, third speed respectively.
Manual speed setting. Check the scroll bar to activate it.
Ventilation
Vento Expert
The ventilator operates either in the extract or supply mode at the set
speed. The fan rotation direction depends on the position of the DIP
switch 3.
Vento Expert Duo
One fan runs in the extract mode and the other one in the supply mode
at the same speed. The air direction is not changed.
Regeneration mode
The fan rotation direction changes to opposite each 70 seconds. This
operation mode enables heat regeneration.
Supply mode
In this mode the Vento Expert ventilator runs exclusively in the supply
mode. The ventilator Vento Expert Duo goes to the
Ventilation mode
.
Night mode.
Activation of the first speed timer (the default setting is 8
hours, adjustable in the menu
Settings - Timers).
Scheduler.
Activation of the week scheduled operation.
Party mode.
Activation of the third speed timer without changing the
ventilator operation mode (4 hours by default, adjustable in the menu
Settings-Timers).
DESCRIPTION OF MOBILE APPLICATION INDICATORS
Current type of connection to the ventilator.
Home connection or connection via a cloud server through Internet respectively.
Indicator of activation of the third speed after actuation of any sensor.
When this mode is active, all the other modes are disabled. After countdown of the turn-off delay timer (default
setting 30 minutes) the ventilator reverts to previous mode. Press the
Power button
to deactivate this operation
mode.
Humidity indicator. It indicates humidity above the set point.
External relay sensor indicator. It indicates actuation of the external relay sensor.
External analogue 0-10V sensor indicator. It indicates exceeding the set point on the external sensor.
Alarm indicator. In case of alarm glows the indicator with two colours:
The indicator glows red in case of alarm shutdown of the ventilator.
The indicator glows orange if battery is not available or the battery charge is low.
Filter replacement indicator. To reset the filter timer go to
Menu - Settings - Filter
.
When simultaneously activating several operation modes that exclude each other, the operation mode selection is done according to
the following priority:
1. Night mode timer or Party mode timer.
2. Standby.
3. Boost.
4. Schedule
5. Regular mode.