KOMFORT EC SKE270-1.5

BLAUBERG Ventilatoren GmbH Company is happy to offer your attention 

a new heat recovery air handling unit 

KOMFORT EC SKE270-1.5

 with 

integrated kitchen hood.

INTRODUCTION

The present operation manual contains a technical description, technical 

data sheets, operation and mounting guidelines, safety precautions and 

warnings for safe and correct operation of the unit.  

Read carefully and understand the operation manual, especially the safety 

requirements, before the unit mounting and start up.

Keep the operation manual available as long as you use the unit.

GENERAL

The heat recovery air handling unit KOMFORT EC SKE270-1.5 with integrated 

kitchen hood is designed for efficient and energy saving ventilation of 

domestic premises. 

The unit is not a ready to use product but a component part of central air 

conditioning and ventilation network. 

The unit is designed for wall mounting. 

The unit is available for round Ø125 mm air ducts.

The unit is rated for indoor application at ambient temperature from +1 °C 

up to +60 °C and relative humidity not exceeding 80%. The transported air 

temperature is allowed from -25 °C up to +60 °C.

Hazardous parts access and water ingress protection rating:

  Unit motors - IP 44;

  Assembled unit connected to air ducts - IP 22.

The unit design is regularly improved, so some models can slightly differ 

from those ones described in this service instruction.

SAFETY RULES

All operations related to the unit electrical connections, servicing and 

repair works are allowed only after the unit disconnection from power mains.  

The unit is rated as a Class I electrical appliance.

All mounting and servicing operations are allowed by duly qualified 

personnel. 

Please follow the safety regulations and working instructions (DIN EN 50 

110, IEC 364).

Make sure the impeller and the casing are not damaged before connecting 

the unit to power mains. The casing internals must be free of any foreign 

objects which can damage the impeller blades.

The unit maintenance and repair is allowed only after power cut-off and full 

stop of the rotating parts.

Misuse of the unit or any unauthorized modification are not allowed. 

The unit is designed for connection to ac single-phase power mains, see 

«Technical Data». 

The unit is rated for permanent operation.

Take steps to prevent ingress of smoke, carbon monoxide and other 

combustion products into the room through open chimney flues or other 

fire-protection devices. Sufficient air supply must be provided for proper 

combustion and exhaust of gases through the chimney of fuel burning 

equipment to prevent back drafting.  The maximum permitted pressure 

difference per living units is 4 Pa.

The transported air must not contain any dust or other solid impurities, 

sticky substances or fibrous materials.

The unit is not rated for operation in a flammable or explosive medium. 

Fulfil the operation manual requirements to ensure a trouble-free and long 

service life of the unit. 

TRANSPORTATION AND STORAGE RULES

Transportation of the unit is allowed by any vehicle provided the unit is 

transported in the original package and is protected against weather and 

mechanical damages. 

Use hoist machinery for handling and transportation to prevent possible 

mechanical damages of the unit. Fulfil the requirements for transportation of 

the specified cargo type during cargo-handling operations. 

Store the unit in a dry and cool place in the original packing.

The storage environment must not be subjected to any aggressive and/

or chemical evaporations, admixtures, foreign objects that may provoke 

corrosion and damage connection tightness. 

Store the unit in an environment with minimized risk of mechanical 

damages, temperature and humidity fluctuations. 

Do not expose the unit to the temperatures below  +5 °C and above  +40 

°C .

Connection of the unit to power mains is allowed after the unit has been 

kept indoor for minimum two hours.

MANUFACTURER’S WARRANTY

The unit complies with the requirements according to the EU norms 

and directives, to the relevant EU-Low Voltage Equipment Directives, EU-

Directives on Electromagnetic Compatibility. 

We hereby declare that the unit complies with the essential protection 

requirements of Electromagnetic Council Directive 2004/108/EC, 89/336/EEC 

and Low Voltage Directive 2006/95/EC, 73/23/EEC and CE-marking Directive 

93/68/EEC on the approximation of the laws of the Member States relating to 

electromagnetic compatibility. This certificate is issued following test carried 

out on samples of the product referred to above. Assessment of compliance of 

the product with the requirements relating to electromagnetic compatibility 

was based on the following standards.

The manufacturer hereby warrants normal operation of the unit over the 

period of two years from the retail sale date provided observance of the 

installation and operation regulations.

In case of failure due to manufacturing fault during the warranty period the 

consumer has the right to exchange it.

The replacement is offered by the Seller. 

If case of no confirmation of the sale date, the warranty period shall be 

calculated from the manufacturing date.

The manufacturer shall not be liable for any damage resulting from any 

misuse of or gross mechanical interference with the unit.

The manufacturer is not responsible for the damages resulted due to the 

use of  third party equipment or to third party equipment.

                   

WARNING

 

Do not dispose in domestic waste. 

The unit contains in part material that 

can be recycled and in part substances 

that should not end up as domestic waste. Dispose 

of the unit once it has reached the end of its work-

ing life according to the regulations valid in your 

country.

 

                  

WARNING

The unit is not allowed for use by chil-

dren and persons with reduced physi-

cal, mental or sensory capacities, without proper 

practical experience or expertise, unless they are 

controlled or instructed on the product operation 

by the person(s) responsible for their safety. Super-

vise the children and do not let them play with the 

product. 

!

KOMFORT_EC_SKE270_v2(4)_EN.indd   3

07.08.2015   14:25:41

Summary of Contents for KOMFORT EC SKE270-1.5

Page 1: ...OPERATION MANUAL KOMFORT EC SKE270 1 5 KITCHEN HEAT RECOVERY AIR HANDLING UNIT KOMFORT_EC_SKE270_v2 4 _EN indd 1 07 08 2015 14 25 40 ...

Page 2: ...cturer s warranty 4 Design 4 Operating logic 5 Delivery set 5 Technical data 6 Mounting 7 Condensate drainage 8 Connection to power mains 9 Unit control 14 Maintenance 16 Troubleshooting and fault handling 18 Acceptance certificate 18 Connection certificate 18 Warranty card CONTENTS KOMFORT_EC_SKE270_v2 4 _EN indd 2 07 08 2015 14 25 40 ...

Page 3: ...d long service life of the unit TRANSPORTATION AND STORAGE RULES Transportation of the unit is allowed by any vehicle provided the unit is transported in the original package and is protected against weather and mechanical damages Use hoist machinery for handling and transportation to prevent possible mechanical damages of the unit Fulfil the requirements for transportation of the specified cargo ...

Page 4: ...d for condensate collection and drainage The unit is equipped with an electric heater for operation during cold seasonsatlowoutsidetemperature Theintegratedelectricheaterisactivated to warm up supply air up to 30 C if set indoor air temperature may not be reached by means of heat recovery only Once the set temperature is reached the electric heater turns automatically off The electric heater is eq...

Page 5: ...ted air ducts diameter mm 125 Weight kg 38 Heat recovery efficiency from 85 up to 98 Heat exchanger type counter flow Heat exchanger material polystyrene option extra replaceable filters are special accessories and available on separate order Parameters Ambient temperature C 0 up to 40 Relative humidity 5 up to 90 no condensation Cable cross section mm2 0 18 up to 0 35 Material ABS plastic Dimensi...

Page 6: ...ll a duct temperature sensor at least 1 m away from the supply air duct to spigot connection The duct supply air temperature sensor is mounted as follows Drill a Ø9 mm hole in the air duct Install a sensor in the hole Fix the sensor in place Ensure airtight connection of the sensor and the air duct joint MOUNTING Safety precautions The unit must be mounted to a rigid and stable structure Before st...

Page 7: ...ays filled with water Provide free drainage for the condensed water otherwise it is accumulated inside the unit which may result in the equipment damage and condensate outflow to the room The condensate drain system is suitable for indoor frost free application with the ambient temperature above 0 C If the expected ambient temperature is below 0 C provide heating for the drain system WARNING In ca...

Page 8: ...ctivated the normally opened dry contact closes and switches the unit to maximum speed Connect extra contacts according to the electric wiring diagram fig 7 Route the wires through the electric lead in in the upper part of the air handling unit Fig 7 External wiring diagram Cut power supply to the unit off by turning the automatic electric switch QF to OFF position prior to any operations Take ste...

Page 9: ...rol panel display in OFF mode Fig 10 Wall mounted control panel display in ON mode Unit ON OFF Operation control buttons see details below Fan speed control buttons Remote controller Remote Controller Unit ON OFF Fan speed UP Heater ON Heater OFF Fan speed DOWN Low speed ON High speed ON Medium speed ON Scheduled operation ON Timer ON OFF Wall mounted control panel Countdown indication of the time...

Page 10: ...heatremovalfromtheheatingelements 4 Timer The timer ensures automatic changeover from a current operation mode into high speed mode and revert to the previous operation mode in set time period To activate deactivate timer using the wall mounted control panel press the button once to set the timer for 20 minutes each subsequent pressing prolongs the timer operation for 10 minutes till maximum 60 mi...

Page 11: ... Supply fan power step up down Each pressing increases decreases the fan power by 1 press and hold press stepping up stepping down Current supply fan power indicator during set up Current supply fan power indicator Supply fan adjustment indicator when pressed Extract fan power step up down Each pressing increases decreases the fan power by 1 press and hold press stepping up stepping down Current e...

Page 12: ...ng temperature to communicate the need of filter cleaning or replacement Clean or replace the filters and then reset the motor meter Filter replacement indicator Press the button on the control panel to turn the unit off and disconnect it from power supply Replace the filters as stated in the Maintenance section After the filter replacement connect the unit to power supply and press a respective b...

Page 13: ...ater on press and hold press Selection of the scheduled operation mode parameters The set point blinks during setup press and hold press or Setting the required set point Parameters for scheduled operation setup Entry number each week day has four entries Week day setting week day Heater operation status setting the heater operating status for a current entry Fan speed setting the fan speed for a ...

Page 14: ...replaced Install dry filters only Contact a local distributor for the filters stated above in the section Technical data Dirty filters are not considered as a warranty case Replace immediately humid and mouldy filters Filter removing as follows Make sure the unit is disconnected from power mains QF Remove the screws Open the unit front panel and disconnect the control panel After that remove the t...

Page 15: ...se its clogging Pour a drain pan under the unit with water to check free water flow Clean a U trap and the drain system if required 6 Supply air flow control twice per year Check the supply grille and remove foreign objects to maintain free air intake 7 Air ducts maintenance once in 5 years The regular unit maintenance in compliance with the above rules may not completely prevent dust ingress into...

Page 16: ...rvice centre or by a service expert duly authorized for unassisted operations at the units up to 1000 V after careful reading of the operation manual Freeze protection sensor drop off indicator Duct temperature sensor drop off indicator Temperature sensor failure Overheating of heating elements ALARM INDICATION REMEDY Overheating of the heating elements Overheating of the heating elements Reset th...

Page 17: ...les are closed or soiled Remove and clean the air dampers the supply diffusers the exhaust grilles to ensure free air flow Low supply air temperature The extract filter is soiled Clean or replace the extract filter The heat exchanger is iced Check the heat exchanger condition Shutdown the unit if required and turn it on after the freezing danger is no longer imminent Noise vibration The impeller i...

Page 18: ...23 EEC and CE marking Directive 93 68 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility This certificate is issued following test carried out on samples of the product referred to above Approval mark Manufacturing date____________________ Company Name Date Signature Kitchen heat recovery air handling unit KOMFORT EC SKE270 1 5 is connected to power...

Page 19: ...________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________...

Page 20: ...www blaubergventilatoren de KOMFORT EC SKE270 1 5 v 2 4 EN KOMFORT_EC_SKE270_v2 4 _EN indd 20 07 08 2015 14 26 07 ...

Reviews: