background image

 

 

10 

 

 
Filter replacement 

By mounting new filter cartridges pay attention that their gasket at the upper side lies firm at the sheet steel 
of the filter chamber. A tilt of the filter cartridge result in leakage and they suction contaminants in the clean 
part and consequently blow them backwards in the outer air.  
 

Pulse system 

The dust collector is provided with an air pulse cleaning system which increases the life of the filter cartridges. 
The system works by use of pressurized air, built up by a compressor 
The air is leaded through a water separator to the pulse system.  
The cooled air passes a control valve, which regulates the systems pressure, and then builds up pressure in 
the pulse tank.  
 
Normally the pressure in the system is 5 – 5.5 bar. The safety valve mounted on the compressor is activated 
at approximately 10 bar. 
This provision is to ensure that when there is a defect in the Control valve, the pressure in the pulse tank 
remains within safe limits.  
 
If the pressure of 5 bar is not reached, it is possible that there is a leakage in the pneumatic circuit or the air 
filter of the compressor is dirty. 
 
When there is pressure but the pulse system does not function, there might be a problem in the electrical 
system which controls the pulsing system. Check the wiring and the PLC-settings. 
 

 
 
Advised is to take contact with Blastrac Support in order to prevent operational problems. 
 
 

Compressor 

 

Replacement or cleaning of the air filter of the compressor (item 11 page 5) is depending on the environment 
in which the dust collector is operating.   
 

 

Advised is to take contact with Blastrac support in order to prevent operational problems. 

 

 
 
 
 
 
 

Summary of Contents for BDC-99

Page 1: ...OPERATING MANUAL BDC 99 VERSION 1 2 www blastrac com 1 800 256 3440...

Page 2: ...equirements of the European Directive for machine Safety In case of changes to the machine without our written authorization this declaration loses its validity Model Blastrac BDC 99 Serial number xxx...

Page 3: ...afety precautions with regard to transport Safety regulations with regard to maintenance 4 Before operation 08 Checkpoints of power supply 5 Operation 08 Starting stopping the machine Work with the ma...

Page 4: ...AA Class Designation L Low risk for separating dust with an exposure limit value of over 1 mg m3 depending on the volume occupied M BDC 99 Medium risk for separating dust with an exposure limit value...

Page 5: ...act plate 5 Manometer shows the pressure of the air tank The pulse to clean the filters must be given at 5 5 5 bar 6 Drain valve Open regular to remove water from the air tank 7 Pressure valve must be...

Page 6: ...e hazardous zone take precautions to prevent dust from escaping Safety precautions with regard to maintenance To allow the user to carry out maintenance operations the dust collector must be disassemb...

Page 7: ...onnection do not change this and use always earthed cables with an earthed plug Connect the main power supply cable to an installation with an earth leakage circuit breaker Inspect and test the electr...

Page 8: ...Switch on the main switch Switch on first the compressor motor Secondly switch on the fan motor Carry out this actions in opposite sequence to stop the machine Work with the machine Regular check the...

Page 9: ...ieved during the corresponding period the period can be extended However a full overhaul must be carried out at least once a year Due to different working conditions it can t be foreseen how frequentl...

Page 10: ...n the system is 5 5 5 bar The safety valve mounted on the compressor is activated at approximately 10 bar This provision is to ensure that when there is a defect in the Control valve the pressure in t...

Page 11: ...k by the use of high class hepa filter Applied by us filters have high filtration efficiency starting from just 99 95 7 2 Difference vacuum gauge A vacuum gauge measures the difference between the und...

Page 12: ...4 x 16mm2 15m 4 x 16mm2 15m Available plug connections 5 pole 63 Ampere 5 pole 63 Ampere Air flow with 20m hose 6 and medium shot blaster 1410m3 hr Air flow without hose 2654m3 hr Vacuum 66 mbar Dust...

Page 13: ...noted on shipping receipt Hand Tool Products Blastrac warrants its BLASTRAC Hand Tool Products including hand grinders and accessories against defects in material and workmanship under normal and prop...

Page 14: ...otors batteries tires and all other parts See component manufacture warranty 7 Blastrac reserves the right to make product changes or improvements without prior notice and without undertaking any obli...

Page 15: ...Warranty Registration IMPORTANT To ensure that your Blastrac machine is covered under warranty please provide the information recorded here by registering online at blastrac com or complete this page...

Page 16: ...Blastrac 13201 North Santa Fe Avenue Oklahoma City OK 73114 800 256 3440 Fax 866 485 1046 www blastrac com...

Reviews: