background image

 

 

 

 

Safety regulations 

 
The following sticker is placed on the machine. 

 
 
 
 
 
 
 

 
Meanings of these symbols are: 

 

Ear protection is obliged 

 

Safety glasses with lateral protection are obliged 

 

CE-mark on this machine 

 

Safety shoes obliged 

 

Consult the manual before operating the machine 

 
 
Personnel must tie back long hair and not wear loose clothing or jewelry including rings. 
 
Wear gloves and dust mask during operating the machine. 

 

Persons who are not operating the machine must not be permitted to stay in the surrounding area of 
the machine. 

 

Don’t change anything on the machine. Use always cables which are approved and safety earthed 
(extend) cables. The machine is always equipped with an earthed connection, do not change this and 
use always earthed cables with an earthed plug. 

 

Connect the main power supply cable to an installation with an earth leakage circuit breaker. 

 

Inspect and test the electrical components regularly. The electrical components have to satisfy to the 
requirements which apply to these components. 

 

Always call a skilled electrician or your distributor when you have questions about the safety of the 
electrical components. 

 

Work on electrical equipment or operating materials may only be undertaken by a skilled electrician or 
by trained persons under the guidance and supervision of a skilled electrician as well as in accordance 
with the electrical engineering regulations. 

 

Pull out the main plug during inspections and repair operations on the machine and turn main switch. 

 

Never operate the machine when the surface is wet. 

 

Never use the machine in the rain. 

 

 
 

 

 

 

 

 

 
 

 

Summary of Contents for BDC-99

Page 1: ...OPERATING MANUAL BDC 99 VERSION 1 2 www blastrac com 1 800 256 3440...

Page 2: ...equirements of the European Directive for machine Safety In case of changes to the machine without our written authorization this declaration loses its validity Model Blastrac BDC 99 Serial number xxx...

Page 3: ...afety precautions with regard to transport Safety regulations with regard to maintenance 4 Before operation 08 Checkpoints of power supply 5 Operation 08 Starting stopping the machine Work with the ma...

Page 4: ...AA Class Designation L Low risk for separating dust with an exposure limit value of over 1 mg m3 depending on the volume occupied M BDC 99 Medium risk for separating dust with an exposure limit value...

Page 5: ...act plate 5 Manometer shows the pressure of the air tank The pulse to clean the filters must be given at 5 5 5 bar 6 Drain valve Open regular to remove water from the air tank 7 Pressure valve must be...

Page 6: ...e hazardous zone take precautions to prevent dust from escaping Safety precautions with regard to maintenance To allow the user to carry out maintenance operations the dust collector must be disassemb...

Page 7: ...onnection do not change this and use always earthed cables with an earthed plug Connect the main power supply cable to an installation with an earth leakage circuit breaker Inspect and test the electr...

Page 8: ...Switch on the main switch Switch on first the compressor motor Secondly switch on the fan motor Carry out this actions in opposite sequence to stop the machine Work with the machine Regular check the...

Page 9: ...ieved during the corresponding period the period can be extended However a full overhaul must be carried out at least once a year Due to different working conditions it can t be foreseen how frequentl...

Page 10: ...n the system is 5 5 5 bar The safety valve mounted on the compressor is activated at approximately 10 bar This provision is to ensure that when there is a defect in the Control valve the pressure in t...

Page 11: ...k by the use of high class hepa filter Applied by us filters have high filtration efficiency starting from just 99 95 7 2 Difference vacuum gauge A vacuum gauge measures the difference between the und...

Page 12: ...4 x 16mm2 15m 4 x 16mm2 15m Available plug connections 5 pole 63 Ampere 5 pole 63 Ampere Air flow with 20m hose 6 and medium shot blaster 1410m3 hr Air flow without hose 2654m3 hr Vacuum 66 mbar Dust...

Page 13: ...noted on shipping receipt Hand Tool Products Blastrac warrants its BLASTRAC Hand Tool Products including hand grinders and accessories against defects in material and workmanship under normal and prop...

Page 14: ...otors batteries tires and all other parts See component manufacture warranty 7 Blastrac reserves the right to make product changes or improvements without prior notice and without undertaking any obli...

Page 15: ...Warranty Registration IMPORTANT To ensure that your Blastrac machine is covered under warranty please provide the information recorded here by registering online at blastrac com or complete this page...

Page 16: ...Blastrac 13201 North Santa Fe Avenue Oklahoma City OK 73114 800 256 3440 Fax 866 485 1046 www blastrac com...

Reviews: