background image

 

 

 

 
 
 

 
 
 
 

1  Dust bin kit 

2  Longo pack kit 

3  Big bag kit 

4  Rubber impact plate 

Manometer, shows the pressure of the air 
tank. The pulse to clean the filters must be 
given at 5 – 5.5 bar. 

6  Drain valve. Open regular to remove water 

from the air tank. 

7  Pressure valve, must be set on 5 - 5.5 bar 

8  Water separator 

9  Air filter compressor 

 
 
 

 
 
 
 

Summary of Contents for BDC-99

Page 1: ...OPERATING MANUAL BDC 99 VERSION 1 2 www blastrac com 1 800 256 3440...

Page 2: ...equirements of the European Directive for machine Safety In case of changes to the machine without our written authorization this declaration loses its validity Model Blastrac BDC 99 Serial number xxx...

Page 3: ...afety precautions with regard to transport Safety regulations with regard to maintenance 4 Before operation 08 Checkpoints of power supply 5 Operation 08 Starting stopping the machine Work with the ma...

Page 4: ...AA Class Designation L Low risk for separating dust with an exposure limit value of over 1 mg m3 depending on the volume occupied M BDC 99 Medium risk for separating dust with an exposure limit value...

Page 5: ...act plate 5 Manometer shows the pressure of the air tank The pulse to clean the filters must be given at 5 5 5 bar 6 Drain valve Open regular to remove water from the air tank 7 Pressure valve must be...

Page 6: ...e hazardous zone take precautions to prevent dust from escaping Safety precautions with regard to maintenance To allow the user to carry out maintenance operations the dust collector must be disassemb...

Page 7: ...onnection do not change this and use always earthed cables with an earthed plug Connect the main power supply cable to an installation with an earth leakage circuit breaker Inspect and test the electr...

Page 8: ...Switch on the main switch Switch on first the compressor motor Secondly switch on the fan motor Carry out this actions in opposite sequence to stop the machine Work with the machine Regular check the...

Page 9: ...ieved during the corresponding period the period can be extended However a full overhaul must be carried out at least once a year Due to different working conditions it can t be foreseen how frequentl...

Page 10: ...n the system is 5 5 5 bar The safety valve mounted on the compressor is activated at approximately 10 bar This provision is to ensure that when there is a defect in the Control valve the pressure in t...

Page 11: ...k by the use of high class hepa filter Applied by us filters have high filtration efficiency starting from just 99 95 7 2 Difference vacuum gauge A vacuum gauge measures the difference between the und...

Page 12: ...4 x 16mm2 15m 4 x 16mm2 15m Available plug connections 5 pole 63 Ampere 5 pole 63 Ampere Air flow with 20m hose 6 and medium shot blaster 1410m3 hr Air flow without hose 2654m3 hr Vacuum 66 mbar Dust...

Page 13: ...noted on shipping receipt Hand Tool Products Blastrac warrants its BLASTRAC Hand Tool Products including hand grinders and accessories against defects in material and workmanship under normal and prop...

Page 14: ...otors batteries tires and all other parts See component manufacture warranty 7 Blastrac reserves the right to make product changes or improvements without prior notice and without undertaking any obli...

Page 15: ...Warranty Registration IMPORTANT To ensure that your Blastrac machine is covered under warranty please provide the information recorded here by registering online at blastrac com or complete this page...

Page 16: ...Blastrac 13201 North Santa Fe Avenue Oklahoma City OK 73114 800 256 3440 Fax 866 485 1046 www blastrac com...

Reviews: