Blagdon Minipond 12000 Manual Download Page 9

2

1

2

3

Electrical installation - UVC Models

The power supply must meet the specifications on the product.

The UVC is intended to be used with either a weatherproof cable connector or 
permanently connected to the fixed wiring in the main system other than by means  
of a plug and socket.

The cores in the supply cable are coloured in accordance with the following code:   

Brown = Live, Blue = Neutral.

Do not use the supply cable to lift the UVC as this may cause damage.

Testing/installing the UVC lamp

1. 

Unscrew the UVC electronics cover cap.

2. 

Inspect the UVC cap and Quartz sleeve for water leaks.

3. 

If there are no signs of leakage reverse the procedure ensuring that the Cover o ring is in place.

If there has been any damage to the unit please return to the point of purchase for  
inspection. This test should be repeated whenever the the bulb or quartz is changed.

Warning direct exposure to UVC light can damage your eyes or skin.

This unit is protected by a micro switch that prevents the UVC light  
from illuminating when the cover is removed even if the power is on. 
In order to check that the UVC lamp  is operating remove  
the spay bar and hold a piece of plain paper up to  
the the UVC outlet a faint blue reflection should  
be seen.This operation may be needed to be  
carried out at dusk as UVC lamps emit a  
dim blue light under normal operation.

INSTALLATION

ELECTRICAL INSTALLATION

WARNING:

 

 

A Residual Current Device (RCD), also known as the Residual Current 

Circuit Breaker (RCCB), with a tripping current not exceeding 30mA must be installed 
in the supply circuit. A means of disconnection from the supply having a contact 
separation of at least 3mm in all poles must be incorporated in the fixed wiring.

IMPORTANT:

 

 Ensure that the mains supply is switched off and the power isolated before  

removing the UVC cover.

7

17.562 Blagdon_Minipond filter instructions_9000/12000 AW3.indd   10

14/07/2017   17:00

Summary of Contents for Minipond 12000

Page 1: ...ww blagdonwatergardening co uk www interpetcentral com www pondaquariumproblemsolver co uk blagdon Minipond UV pond filter system 17 562 Blagdon_Minipond filter instructions_9000 12000 AW3 indd 2 14 0...

Page 2: ...d Water Garden Filtration System Manufactured with advanced technology to create a clean and healthy pond for your fish IMPORTANT Please attach proof of purchase to this manual and file in a safe plac...

Page 3: ...r 6 Testing installing replacing the UVC lamp 7 Electrical installation 7 8 Maintenance 8 Dismantling the filter 8 Routine maintenance 9 How it works flow detail 9 Annual maintenance 10 Winter storage...

Page 4: ...artridge clip 13 Filter pad cartridge 1040617 14 Spray bar cap 15 Spray bar 16 spray bar nut 1040624 17 Spray bar O ring gasket 18 UVC feet hinge locating screws 1040631 19 Filter lid 1040648 20 UVC e...

Page 5: ...er 75cm deep with fish in shade Over 75cm deep with fish in full sun Under 75cm deep with fish in full sun Under 75cm deep with Koi in full sun MINIPOND 9 000 9 000 ltrs 1 980 gals 4 500 ltrs 990 gals...

Page 6: ...e 15cm UVC electronics access must not be below ground level WATERFALL ABOVE GROUND BELOW GROUND Filter Outlet Hose Installation PUMP MINIPOND FILTER above ground Filter outlet to Pond FOUNTAIN HOSE F...

Page 7: ...mm 19mm 12 5mm CUT CUT Important The outlet hose should be smooth bore not corrugated pipe installed over as short a distance as possible with no kinks or bends We recommend that heavy duty smooth bor...

Page 8: ...is to transfer dirty water from the pond to the Minipond filter Placing the pump at the opposite end of the pond to the filter will give the best results Foam free pump designs will give optimum Mini...

Page 9: ...is changed Warning direct exposure to UVC light can damage your eyes or skin This unit is protected by a micro switch that prevents the UVC light from illuminating when the cover is removed even if t...

Page 10: ...regulations Failure to comply is a criminal offence If the installation of this product is not carried out by a competent electrician who is registered under the Part P self certification scheme then...

Page 11: ...or hose Adding Blagdon Bio Start after filter maintenance will help replenish these beneficial bacterial populations and is highly recommended during the first two months of operation when the filter...

Page 12: ...ee diagram on page 8 and codes descriptions on page 2 Annual Maintenance Check for wear Once a year you should dismantle your Minipond filter Dismantle the filter examining all the parts for wear or d...

Page 13: ...to trap the fine waste Treat with Blagdon Clear Pond treatment Do not clean the foams until the filter foam chamber starts to overflow into the carbon wool chamber The water is extremely dirty remove...

Page 14: ...o know your filter diagram and parts codes The filter is too small for the pond check the filter selection chart The UVC quartz sleeve is dirty or coated in lime scale Gently remove the quartz sleeve...

Page 15: ...lt the Consumer Advice Line and follow any advice to correct the situation See details below Refunds can only be authorised by Interpet Blagdon CONSUMER ADVICE CONTACT DETAILS Interpet Blagdon Consume...

Page 16: ...nd value for money for our customers Our products are brought together with half a century of expertise and knowledge so you can be assured of a successful and creative water garden Interpet Vincent L...