46
Fig. 8.2
Alpha E-Tec S 20, 30 and 35 - Component Replacement
8.11 PRIMARY HEAT EXCHANGER - Fig. 7.6
Gain access and drain the boiler heating circuit as described in Sections 8.1 and 8.2.
1. Remove the condensate trap assembly as described in Section 8.10.
2. Remove the burner as described in Section 7.3.
3. Unplug the connection from the flue temperature sensor and remove the sensor as described in Section 8.6.
4. Disconnect the condensate drain pipe by pulling its rubber connector from the heat exchanger.
5. Unscrew the flue sampling point cap and remove the complete fitting from the top of the case.
6. Disconnect the flue sensor wires and remove the lower retaining screw on the bottom of the heat exchanger..
7. Remove the heating flow and return pipe retaining clips from the primary heat exchanger and pull the pipes downwards
from the heat exchanger connections.
8. Lift the heat exchanger upwards and forwards to disconnect it from the bottom bracket and withdraw it from the boiler.
9. Refit the flue temperature sensor.
10. Reassemble in reverse order using the lubricant supplied with the heat exchanger kit.
Note:
Lubricating the seals with soap and water will aid assembly.
11. Refill boiler, pressurise the system and visually inspect for leaks.
12. Test the boiler, check the ignition and test the combustion as described in Section 6.
8.12 PRESSURE GAUGE - Fig. 8.1
Gain access and drain the heating circuit as described in Sections 8.1 and 8.2.
1. Depress the two lugs on the pressure gauge and pull it out of the control panel.
2. Withdraw the retaining clip securing the pressure gauge sensor (just to the left of the automatic air vent) and withdraw
the sensor.
Note:
This is a direct sensor, ensure all electrical components are protected from water escape.
3. Remove the main cable grommet in the bottom panel and remove the sensor tube.
4. Fit the new gauge sensor using a new 'O' ring on the connection if necessary.
5. Reassemble in reverse order.
6. Refill and pressurise the system. (Refer to Commissioning, Section 6.1).
Condensate trap
Gas valve
Summary of Contents for BLADE TWIN PLUS TPWH60
Page 2: ......
Page 6: ...4 Blade 60 80 Twin Plus Water Heater Manual July 2020 3 0 BLADE WATER HEATER SCHEMATIC LAYOUT ...
Page 7: ...Blade 60 80 Twin Plus Water Heater Manual July 2020 5 3 1 SCHEMATIC LEGEND ...
Page 18: ...16 Blade 60 80 Twin Plus Water Heater Manual July 2020 10 0 INSTALLATION SCHEMATIC LAYOUT ...
Page 21: ...Blade 60 80 Twin Plus Water Heater Manual July 2020 19 13 0 WIRING DIAGRAM ...
Page 29: ...Blade 60 80 Twin Plus Water Heater Manual July 2020 27 Notes ...
Page 30: ...APPENDIX A ALPHA BOILER MANUAL ...
Page 89: ...59 Alpha E Tec S 20 30 and 35 Page intentionally Blank ...
Page 99: ...Blade 60 80 Twin Plus Water Heater Manual July 2020 29 APPENDIX B DAB PUMP MANUAL ...
Page 113: ...ENGLISH 41 It is dangerous to touch the circulator DANGER OF SCALDING ...
Page 123: ...ENGLISH 51 18 PERFORMANCE CURVES EVOSTA2 40 70 XXX ...
Page 124: ...ENGLISH 52 EVOSTA2 80 XXX ...
Page 125: ...ENGLISH 53 EVOSTA3 40 XXX ...
Page 126: ...ENGLISH 54 EVOSTA3 60 XXX ...
Page 127: ...ENGLISH 55 EVOSTA3 80 XXX ...