G7 DOCK CARE 

6.1

 

MAINTENANCE 

To make sure G7 Dock is in working condition, ensure the following:  

 

Gas valves inside the G7 Dock lid move easily and are free of debris.  

 

Gas inlets and outlet are free of debris.  

 

Charge clip is free of debris. 

To clean G7 Dock, disconnect from power and wipe down with a damp cloth. Do not use 
pressure spray or cleaning solvents. 

For best performance, G7 Dock should be operated in a dry and dust-free environment. 

7

 

TROUBLESHOOTING 

7.1

 

SETUP FAQ 

Why is G7 telling me to close the lid when I have already closed it? 

If your device is telling you to close the lid when you try to run a bump test or calibration, it is 
likely that the lid has not been closed properly. Ensure that you press down firmly on both 
sides of the lid so that both release tabs click into place. 

Why is my device unresponsive when I put it into G7 Dock? 

If your device does not respond when placed into G7 Dock, it may not be properly connected 
to the dock, or the dock may not be connected to a power supply. Remove your device from 
G7 Dock and check to see if the green power light is on. 

If the power light is on, ensure that: 

 

Charge clips on both the device and dock are connected.  

 

Device clicks into place when set down into the Dock.  

 

Lid is properly closed. Ensure that you press down on both sides so that both release 
tabs click into place.  

 

Charge clips are clean and free of debris. 

Summary of Contents for G7 DOCK

Page 1: ...G7 Dock Technical User Manual...

Page 2: ...TOMIZING INLETS 10 2 3 REACTIVE GASES 10 2 4 CONNECTING G7 DOCK TO A CALIBRATION GAS CYLINDER 10 3 OPERATING 11 3 1 REQUIREMENTS 11 3 2 POWERING ON 11 3 3 PLACING G7 INTO G7 DOCK 12 4 FEATURES 13 4 1...

Page 3: ...Technical User Manual 2022 Blackline Safety Corp 2022 09 26 Rev 11 8 SPECIFICATIONS AND LEGAL NOTICES 18 8 1 DETAILED SPECIFICATIONS 18 8 2 LEGAL NOTICES 19 9 SUPPORT 20 9 1 LEARN MORE 20 9 2 CUSTOME...

Page 4: ...ics recycling authority regarding the disposal of your device Do not dispose Blackline products in your household trash DANGER Do not use G7 Dock in areas classified as hazardous locations where there...

Page 5: ...and to G7 Dock The Blackline Safety Network is the cloud hosted system used to monitor your safety It includes cellular networks satellite networks our Blackline Live cloud based application your moni...

Page 6: ...2022 Blackline Safety Corp G7 Dock Technical User Manual 6 Rev 11 2022 09 26 Dock filter Multi lingual sticker sheet G7 Dock Getting Started Guide 1 4 HARDWARE DETAILS...

Page 7: ...7 G7 Dock Technical User Manual 2022 Blackline Safety Corp 2022 09 26 Rev 11...

Page 8: ...afe exhaust location NOTE You should never plug gas into the Gas out exhaust The next three inlets to the right of the Gas out exhaust are configured to support your selected gases and gas mixtures Th...

Page 9: ...using dock in dusty or humid environments you can attach the optional dock filter subassembly to the purge inlet to ensure dock is being purged with clean air The dock filter subassembly is made up o...

Page 10: ...l2 with G7 Dock you must use the following Inlet 1 which has been optimized for Cl2 and other highly reactive gases based on order of gas calibration or bump testing Teflon lined tubing ACC FEP T2 A s...

Page 11: ...Cl2 Teflon lined tube ACC FEP T2 Stainless steel regulator or a regulator with a Viton valve seat and seals ACC DFR V 120 240 VAC power source and power components NOTE You must use the power compone...

Page 12: ...the two red release tabs until dock s lid clicks open 3 3 PLACING G7 INTO G7 DOCK 1 Slide G7 into G7 Dock s charge clip at an angle Ensure the charge clips of both devices are connected 2 Keeping the...

Page 13: ...Bump testing verifies that your device s gas sensors and notification indicators lights sound and vibration are functioning correctly During a bump test you apply a known concentration and amount of g...

Page 14: ...f gas for a set amount of time This procedure ensures the gas sensor can accurately detect gas levels throughout its operating life The calibration schedule depends on your company s safety policy Bla...

Page 15: ...ork to update G7 Dock configuration settings 4 5 MULTI DOCK SETUP WARNING Do not use a multi dock setup if you are calibrating with Chlorine Cl2 Calibration with Cl2 requires that the tube length be k...

Page 16: ...ibrations and bump tests at the same time without interfering with each other 5 MOUNTING G7 Dock can be placed flat on a table or mounted to a wall 5 1 WALL MOUNTING When mounting G7 Dock to a wall en...

Page 17: ...evice is telling you to close the lid when you try to run a bump test or calibration it is likely that the lid has not been closed properly Ensure that you press down firmly on both sides of the lid s...

Page 18: ...ns in the gas cylinder match Dock configurations If G7 Dock is still not operating correctly please contact Customer Care 8 SPECIFICATIONS AND LEGAL NOTICES 8 1 DETAILED SPECIFICATIONS Size Weight Siz...

Page 19: ...ny names trademarks and service marks are the properties of their respective owners FCC Compliance This equipment has been tested and found to comply with the limits for a Class B digital device pursu...

Page 20: ...o find support and training materials for the G7 Dock 9 2 CUSTOMER CARE For technical support contact our Customer Care team North America 24 hours Toll Free 1 877 869 7212 support blacklinesafety com...

Page 21: ...21 G7 Dock Technical User Manual 2022 Blackline Safety Corp 2022 09 26 Rev 11...

Reviews: