43
CHAPTER 6: Cable Test Descriptions
2. Press SEND (F1) to send the results to the remote unit.
3. Press SUMMARY (F3) or ESC to return to the summary screen.
6.2.5 V
IEWING A
G
RAPH OF
NEXT R
ESULTS
1. From the detail or Summary Results screen, press GRAPH (F2).
2. Press PAIR (F1) to display the results for a different pair combination.
Press SEND (F2) to send the results to the remote unit.
3. Press the arrow keys to move the cursor to a new point on the graph.
The test result at the selected point is displayed below the graph.
4. Press PRINT (F4) to send a comma-separated variable (CSV) listing of
the results to the serial port. This outputs a complete listing of all
NEXT measurements for all pair combinations.
5. Press SUMMARY (F3) or ESC to return to the Summary screen.
NOTE
The test result displayed on the graph is the worst value found within
1-MHz frequency increments for Category 5 and ISO Class D testing. All
test results are available and can be output from the SCAN-LAN Vt.
F1
F2
F3
F4
Cursor
Test Limit
Test Result