141
APPENDIX A: Test Standards
Table A-12. 100BASE T4 Pass/Fail Limits
Length
≤
100 meters
Characteristic Impedance
100±25
Ω
NEXT
Between 1 and 16 MHz, NEXT>Category 3
Channel Limits
Attenuation
Between 1 and 16 MHz, Attenuation
<Category 3 Channel Limits
Split Pair
20 dB
Resistance
<9.9
Ω
Table A-13. TP PMD and TP PMD-REV Pass/Fail Limits
Length
≤
100 meters
Characteristic Impedance
100±25
Ω
NEXT
Between 1 and 100 MHz, NEXT>Category 5
Channel Limits
Attenuation
Between 1 and 100 MHz, Attenuation
<Category 5 Channel Limits
Split Pair
20 dB
Resistance
<9.9
Ω
Table A-14. ISO 11801 Class C Pass/Fail Limits
Length
≤
100 meters
Characteristic Impedance
100±25
Ω
NEXT
Between 1 and 16 MHz, NEXT>ISO 11801
Class C Limits
Attenuation
Between 1 and 16 MHz, Attenuation <ISO
11801 Class C Limits
Split Pair
20 dB
Resistance
<9.9
Ω