background image

3

c)  the wire size is large enough for the AC rating of the charger.

CAUTION: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE: 

Pull by connector rather than cord when disconnecting the extension cord from the 

unit; and by the plug when disconnecting the extension cord from an AC outlet.

CAUTION: TO REDUCE THE RISK OF PROPERTY DAMAGE WHEN CHARGING USING THE 12 VOLT DC METHOD:

• Recharge using this method only when necessary. Frequent use of the 12 Volt DC charging method may shorten battery life.

• DO NOT EXCEED 6 HOURS CHARGING TIME USING THIS METHOD.

SPECIFIC SAFETY INSTRUCTIONS FOR JUMP STARTERS

WARNING: BURST HAZARD

Do not use the unit for charging dry-cell batteries that are commonly used with home appliances. These batteries may burst and cause injury to persons and 

damage property. Use the unit for charging/boosting a lead-acid battery only. It is not intended to supply power to a low-voltage electrical system other than in 

a starter-motor application.

• Use of an attachment not supplied, recommended or sold by manufacturer specifically for use with this unit may result in a risk of electrical shock and injury 

to persons.

WARNING: RISK OF EXPLOSIVE GASES

• Working in the vicinity of a lead acid battery is dangerous. Batteries generate explosive gases during normal battery operation. For this reason, it is of the 

utmost importance that each time before using the jump-starter you read this manual and follow instructions exactly.

• To reduce the risk of battery explosion, follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you 

intend to use in the vicinity of the battery. Review cautionary markings on these products and on the engine.

CAUTION: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE:

• NEVER ATTEMPT TO JUMP-START OR CHARGE A FROZEN BATTERY.

• Vehicles that have on-board computerized systems may be damaged if vehicle battery is jump-started. Before jump-starting, read the vehicle’s owner’s 

manual to confirm that external-starting assistance is suitable.

• When working with lead acid batteries, always make sure immediate assistance is available in case of accident or emergency.

• Always have protective eyewear when using this product: contact with battery acid may cause blindness and/or severe burns. Be aware of first aid 

procedures in case of accidental contact with battery acid.

• Have plenty of fresh water and soap nearby in case battery acid contacts skin.

• Never smoke or allow a spark or flame in vicinity of vehicle battery, engine or power station

• Stay clear of fan blades, belts, pulleys, and other parts that can cause injury to persons.

• Remove personal metal items such as rings, bracelets, necklaces and watches when working with a lead acid battery. A lead acid battery can produce a short 

circuit current high enough to weld a ring, or similar metal object, to skin, causing a severe burn.

• Do not wear vinyl clothing when jump-starting a vehicle. Friction can cause dangerous static-electrical sparks.

• Jump-start procedures should only be performed in a safe, dry, well-ventilated area.

• Always store battery clamps when not in use. Never touch battery clamps together. This can cause dangerous sparks, power arcing and/or explosion.

• When using this unit close to the vehicle’s battery and engine, stand the unit on a flat, stable surface, and be sure to keep all clamps, cords, clothing and body 

parts away from moving vehicle parts.

• Never allow red and black clamps to touch each other or another common metal conductor — this could cause damage to the unit and/or create a sparking/

explosion hazard.

a)  For negative-grounded systems, connect the positive (red) clamp to the positive ungrounded battery post and the negative (black) clamp to the vehicle 

chassis or engine block away from the battery. Do not connect the clamp to the carburetor, fuel lines or sheet-metal body parts. Connect to a heavy gage 

metal part of the frame or engine block.

b)  For positive-grounded systems, connect the negative (black) clamp to the negative ungrounded battery post and the positive (red) clamp to the vehicle 

chassis or engine block away from the battery. Do not connect the clamp to the carburetor, fuel lines or sheet-metal body parts. Connect to a heavy gage 

metal part of the frame or engine block.

• If the connections to the battery’s positive and negative terminals are incorrect, the reverse polarity indicator will light and the unit will sound a continuous 

alarm until the clamps are disconnected. Disconnect clamps and reconnect to battery with correct polarity.

• Always disconnect the negative (black) jumper cable first, followed by the positive (red) jumper cable, except for positive grounded systems.

• Do not expose battery to fire or intense heat since it may explode. Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to 

prevent shorting (shorting can result in injury or fire).

• Place this unit as far away from the battery as cables permit.

• Never allow battery acid to come in contact with this unit.

• Do not operate this unit in a closed area or restrict ventilation in any way.

• This system is designed to be used only on vehicles with a 12 volt DC battery system. Do not connect to a 6 volt or 24 volt battery system.

• This system is not designed to be used as a replacement for a vehicular battery. Do not attempt to operate a vehicle that does not have a battery installed.

• Excessive engine cranking can damage a vehicle’s starter motor. If the engine fails to start after the recommended number of attempts, discontinue jump-

start procedures and look for other problems that may need to be corrected.

• Do not use this jump starter on a watercraft. It is not qualified for marine applications.

• Although this unit contains a non-spillable battery, it is recommended that unit be laid flat during storage, use and recharging. To avoid possible damage that 

may shorten the unit’s working life, protect it from direct sunlight, direct heat and/or moisture.

SPECIFIC SAFETY INSTRUCTIONS FOR INVERTERS

WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK:

• Do not connect to AC distribution wiring.

• Do not make any electrical connections or disconnections in areas designated as IGNITION PROTECTED. This inverter is NOT approved for ignition protected 

areas.

• Never immerse the unit in water or any other liquid, or use when wet.

WARNING: TO REDUCE THE RISK OF FIRE:

• Do not operate near flammable materials, fumes or gases.

• Do not expose to extreme heat or flames.

CAUTION: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE: 

• Disconnect appliance plug from inverter outlet before attempting any repairs to the appliance.

• When an appliance plugged into this unit is used outdoors, use only extension cords intended for use outdoors and so marked.

• Do not attempt to connect the inverter while operating your vehicle. Not paying attention to the road may result in a serious accident.

• Always use the inverter where there is adequate ventilation.

• Always turn the inverter off when not in use.

• Keep in mind that this inverter will not operate high wattage appliances or equipment that produce heat, such as hair dryers, microwave ovens and toasters.

Summary of Contents for PRH5BCA

Page 1: ...20 20 20...

Page 2: ...ODUCT FOR ANY REASON If you have a question or experience a problem with your purchase go to HTTP WWW BACCUSGLOBAL COM for instant answers 24 hours a day If you can t find the answer or do not have ac...

Page 3: ...or further details Stay alert Use common sense Do not operate appliance when you are tired or impaired Check for damaged parts Any part that is damaged should be replaced by the manufacturer before fu...

Page 4: ...other or another common metal conductor this could cause damage to the unit and or create a sparking explosion hazard a For negative grounded systems connect the positive red clamp to the positive ung...

Page 5: ...not operate compressor continuously for longer than approximately 10 minutes depending on ambient temperatures as it may overheat In such event compressor may automatically shut down Turn off the Com...

Page 6: ...ge until two red LED battery status indicators light and one green LED battery status indicator lights or flashes 3 Disconnect the extension cord Notes The unit cannot be overcharged using the AC meth...

Page 7: ...eptacle These devices may damage the inverter or the charging circuit When using a rechargeable device monitor its temperature for the initial ten minutes of use to determine if it produces excessive...

Page 8: ...le is stored in the compressor hose storage compartment The compressor on off switch is located on the front panel of the unit to the right of the air pressure gage refer to the Features section to lo...

Page 9: ...ry to fire or intense heat as it may explode 12 volt DC charger plug fuse replacement may be sold separately The fuse in the plug end of the 12 volt DC charger protects the adapter s charging circuit...

Page 10: ...aintenance free 12 volt DC Area light 3 white LEDs USB port 5V DC 2 000mA 12V DC accessory outlet 12V DC 5A Dual 120V AC outlets 120V AC 60Hz 500W continuous Compressor maximum pressure 120 PSI Import...

Page 11: ...re nouveau produit LIRE AVANT DE RETOURNER CE PRODUIT POUR QUELQUE RAISON QUE CE SOIT Si des questions ou des probl mes surgissent apr s l achat d un produit consulter le site HTTP WWW BACCUSGLOBAL CO...

Page 12: ...fuite la terre doit tre install pour prot ger les circuits ou les prises utilis s Des prises avec disjoncteur de fuite la terre int gr sont aussi disponibles et peuvent tre utilis es comme mesures de...

Page 13: ...ors de l utilisation du produit le contact avec l acide de batterie pourrait provoquer une perte de vue des br lures graves ou les deux Conna tre les mesures de premiers soins en cas de contact accide...

Page 14: ...on en ext rieur et ainsi marqu es Ne pas tenter de connecter l inverseur pendant le fonctionnement de votre v hicule Ne payant pas attention la route peut entra ner un accident grave Toujours utiliser...

Page 15: ...ge 12V CC peut tre vendu s par ment 11 Deux prises de 120V CA sous les couvercles de protection 12 Jauge de pression d air 13 Indicateurs DEL de l tat de la batterie 14 Bouton du niveau de puissance d...

Page 16: ...rise pour accessoires Ne laissez jamais l appareil sans surveillance lors d une charge utilisant cette methode BATTERIE D APPOINT Cette batterie d appoint est munie d un commutateur marche arr t Lorsq...

Page 17: ...recharg e Remarques certains ordinateurs portables peuvent ne pas fonctionner avec cet inverseur Assurez vous que l interrupteur d alimentation de l onduleur est teint lorsque l appareil est en cours...

Page 18: ...la buse Sure Fit Ne serrez pas trop 2 Ins rez l adaptateur dans l objet gonfler 3 Mettre en marche le compresseur interrupteur d alimentation gonflez la pression voulue ou jusqu ce que l objet soit g...

Page 19: ...s que l adaptateur CC ne fonctionne pas il est possible que le fusible soit ouvert grill Remplacement du fusible 1 D vissez le capuchon de la fiche CC dans le sens inverse des aiguilles d une montre 2...

Page 20: ...ns entretien 12V CC Lumi re zone 3 DEL blanches Prise accessoire de CC 12V CC 5A Deux 120V CA sorties 120V CA 60Hz 500W en continu Sortie au port de charge USB 5V CC 2000mA Pression max du compresseur...