background image

5

11

12

13

14

15 16

17

18

19

20

21

22

23

1.  Built-in 120 volt AC charger (under protective cover)

2.  Ergonomic rubber grip handle

3.  Jump-starter power switch

4.  Air hose and Sure Fit

®

 nozzle

5.  Storage compartment cover

6.  Nozzle adapter

7.  Positive (+) red clamp

8.  LED area light

9.  Negative (–) black clamp

10.  12 Volt DC Charging Adapter (may be sold separately)

11.  Dual 120 volt AC outlets (under protective covers)

12.  Air pressure gage

13.  Battery status LED indicators

14.  Battery power level button

15.  Reverse polarity indicator

16.  12 volt DC accessory outlet (under protective cover)

17.  Inverter power switch

18.  Inverter power indicator

19.  Compressor power switch

20.  Area light on/off button

21.  USB power indicator

22.  USB power on/off button

23.  USB charging port (under protective cover)

CHARGING/RECHARGING

Lead-acid batteries require routine maintenance to ensure a full charge and long battery life. All batteries lose energy from self-discharge over time and more 

rapidly at higher temperatures. Therefore, batteries need periodic charging to replace energy lost through self-discharge. When the unit is not in frequent use, 

manufacturer recommends the battery be recharged at least every 30 days.

WARNING: Never attempt to use the AC and DC charging methods at the same time.

Notes: 

This unit is delivered in a partially charged state – you must fully charge it before using it for the first time. Initial AC charge should be for 40 hours.

 

Recharging battery after each use will prolong battery life; frequent heavy discharges between recharges and/or overcharging will reduce battery life.

 

Make sure all other unit functions are turned off during recharging, as this can slow the recharging process.

CAUTION: RISK OF PROPERTY DAMAGE: 

Failure to keep the battery charged will cause permanent damage and result in poor jump starting performance.

IMPORTANT:

 If you know the unit is discharged, but the battery status indicators light as if the unit is fully charged when connected to a charging power source, 

this may be due to the internal battery having high impedance. The manufacturer suggests leaving the unit charging for a period of 40 hours using the built-in 
AC charger before use. 

Charging/Recharging Using the 120V AC Charger and a Standard Household Extension Cord (not included)

1.  Lift the cover built-in 120V AC charger located on the lower left front of the unit (refer to the Features section to locate). Connect an extension cord to the 

unit. Plug the other end of the cord into a standard 120V AC wall outlet.

2.  Charge until two red LED battery status indicators light and one green LED battery status indicator lights or flashes.

3.  Disconnect the extension cord. 

Notes: 

The unit cannot be overcharged using the AC method.

 

The unit will not charge if the inverter power switch is turned on.

Charging/Recharging Using the 12V DC Charging Adapter (may be sold separately)

The DC recharging method will NOT recharge the unit as effectively as recharging from 120 volt AC. The 12 volt DC recharging procedure is recommended only 

when it is necessary, since frequent use of the 12 volt DC recharging procedure may shorten the battery system’s life. 
Charging the unit from an external 12 volt DC power source requires the use of the 12 Volt DC adapter. This adapter has a male DC connector at each end.

1.  Insert the 12 Volt DC Charging Adapter plug with the grooved tip into the vehicle’s 12 volt DC accessory outlet (or other DC power source).

2.  Insert the remaining 12 Volt DC Charging Adapter plug into 12V DC accessory outlet on the front panel of the unit.

3.  Charge the unit until the green FULL indicator lights when the Battery Power Level Button is pressed (with the adapter unplugged from the unit). DO NOT 

CHARGE MORE THAN 6 HOURS MAXIMUM USING THIS METHOD. 

4.  When charging is complete, remove the charging cord and store in a safe place.

Notes: 

Some vehicles require that the ignition be switched to the accessory outlet position in order to power the accessory outlet.

 

Do not leave the unit unattended when charging using the this method.

JUMP-STARTER

This Jump-Starter is equipped with an On/Off Power Switch. Once the connections are properly made, turn the switch on to jump-start the vehicle.

1.  Turn off vehicle ignition and all accessories (radio, A/C, lights, connected cell phone chargers, etc.). Place vehicle in “park” and set the emergency brake. 

2.  Make sure the Jump-Starter Power Switch is turned to off.

3.  Remove jumper clamps from clamp tabs. Connect the red clamp first, then the black clamp. 

4.  Procedure for jump-starting a NEGATIVE GROUNDED SYSTEM (negative battery terminal is connected to chassis) (MOST COMMON)

4a.    Connect positive (+) red clamp to vehicle battery’s positive terminal.

4b.   Connect negative (–) black clamp to chassis or a solid, non-moving, metal vehicle component or body part. Never clamp directly to negative battery 

terminal or moving part. Refer to the automobile owner’s manual.

5.  Procedure for jump-starting POSITIVE GROUND SYSTEMS

Notes: 

In the rare event that the vehicle to be started has a Positive Grounded System (positive battery terminal is connected to chassis), replace steps 4a and 4b above with steps 5a and 

5b, then proceed to step 6.

5a.    Connect negative (–) black clamp to vehicle battery’s negative terminal.

Summary of Contents for PRH5BCA

Page 1: ...20 20 20...

Page 2: ...ODUCT FOR ANY REASON If you have a question or experience a problem with your purchase go to HTTP WWW BACCUSGLOBAL COM for instant answers 24 hours a day If you can t find the answer or do not have ac...

Page 3: ...or further details Stay alert Use common sense Do not operate appliance when you are tired or impaired Check for damaged parts Any part that is damaged should be replaced by the manufacturer before fu...

Page 4: ...other or another common metal conductor this could cause damage to the unit and or create a sparking explosion hazard a For negative grounded systems connect the positive red clamp to the positive ung...

Page 5: ...not operate compressor continuously for longer than approximately 10 minutes depending on ambient temperatures as it may overheat In such event compressor may automatically shut down Turn off the Com...

Page 6: ...ge until two red LED battery status indicators light and one green LED battery status indicator lights or flashes 3 Disconnect the extension cord Notes The unit cannot be overcharged using the AC meth...

Page 7: ...eptacle These devices may damage the inverter or the charging circuit When using a rechargeable device monitor its temperature for the initial ten minutes of use to determine if it produces excessive...

Page 8: ...le is stored in the compressor hose storage compartment The compressor on off switch is located on the front panel of the unit to the right of the air pressure gage refer to the Features section to lo...

Page 9: ...ry to fire or intense heat as it may explode 12 volt DC charger plug fuse replacement may be sold separately The fuse in the plug end of the 12 volt DC charger protects the adapter s charging circuit...

Page 10: ...aintenance free 12 volt DC Area light 3 white LEDs USB port 5V DC 2 000mA 12V DC accessory outlet 12V DC 5A Dual 120V AC outlets 120V AC 60Hz 500W continuous Compressor maximum pressure 120 PSI Import...

Page 11: ...re nouveau produit LIRE AVANT DE RETOURNER CE PRODUIT POUR QUELQUE RAISON QUE CE SOIT Si des questions ou des probl mes surgissent apr s l achat d un produit consulter le site HTTP WWW BACCUSGLOBAL CO...

Page 12: ...fuite la terre doit tre install pour prot ger les circuits ou les prises utilis s Des prises avec disjoncteur de fuite la terre int gr sont aussi disponibles et peuvent tre utilis es comme mesures de...

Page 13: ...ors de l utilisation du produit le contact avec l acide de batterie pourrait provoquer une perte de vue des br lures graves ou les deux Conna tre les mesures de premiers soins en cas de contact accide...

Page 14: ...on en ext rieur et ainsi marqu es Ne pas tenter de connecter l inverseur pendant le fonctionnement de votre v hicule Ne payant pas attention la route peut entra ner un accident grave Toujours utiliser...

Page 15: ...ge 12V CC peut tre vendu s par ment 11 Deux prises de 120V CA sous les couvercles de protection 12 Jauge de pression d air 13 Indicateurs DEL de l tat de la batterie 14 Bouton du niveau de puissance d...

Page 16: ...rise pour accessoires Ne laissez jamais l appareil sans surveillance lors d une charge utilisant cette methode BATTERIE D APPOINT Cette batterie d appoint est munie d un commutateur marche arr t Lorsq...

Page 17: ...recharg e Remarques certains ordinateurs portables peuvent ne pas fonctionner avec cet inverseur Assurez vous que l interrupteur d alimentation de l onduleur est teint lorsque l appareil est en cours...

Page 18: ...la buse Sure Fit Ne serrez pas trop 2 Ins rez l adaptateur dans l objet gonfler 3 Mettre en marche le compresseur interrupteur d alimentation gonflez la pression voulue ou jusqu ce que l objet soit g...

Page 19: ...s que l adaptateur CC ne fonctionne pas il est possible que le fusible soit ouvert grill Remplacement du fusible 1 D vissez le capuchon de la fiche CC dans le sens inverse des aiguilles d une montre 2...

Page 20: ...ns entretien 12V CC Lumi re zone 3 DEL blanches Prise accessoire de CC 12V CC 5A Deux 120V CA sorties 120V CA 60Hz 500W en continu Sortie au port de charge USB 5V CC 2000mA Pression max du compresseur...

Reviews: