40
SERVSWITCH™ PROFESSOR
4.3.14 K
EEP
S
ETTINGS
The Keep Settings command causes
all
of the ServSwitch Professors in your system
to save their keyboard-selectable settings to their nonvolatile memory (NVRAM),
after which they become the new default (loaded at power-up) settings. To enter
the command, press and release the left [Ctrl] key, then type [K]. The ten
keyboard-selectable settings are described in the next nine sections.
4.3.15 S
ET
S
CAN
-D
ELAY
T
IME
Issue the Set Scan-Delay Time command to set the time, in seconds, that the
ServSwitch Professor will pause at each of the stations when it’s scanning them.
The factory-default setting is 5 seconds. To set a different delay time, press and
release the left [Ctrl] key, type [T] followed by the new delay time in seconds (1 to
15), and press [Enter]. Issue the Keep Settings command after you enter this
command.
4.3.16 S
ET
M
INIMUM AND
M
AXIMUM
S
CAN
S
TATIONS
The Minimum and Maximum Scan Stations commands set the range of stations for
which scanning and numeric-order switching occurs. The default Minimum
Station is 1, the default Maximum Station is 16. To set the Minimum Station, press
and release the left [Ctrl] Key, type [<], enter the address of the new Minimum
Scan Station and press [Enter]. To set the Maximum Station, press and release the
left [Ctrl] Key, type [>], enter the address of the new Maximum Scan Station and
press [Enter]. Issue the Keep Settings command after you enter these commands
to save the settings.
Be careful not to accidentally set the Minimum Scan Station to an address higher
than the Maximum Scan Station; if you do, scanning will not work.