REMOTE UNIT CONFIGURATION & OPERATION
32
4.3 Other Remote Configuration & Operation
Options
Scroll Lock Function
Standard and Serial Remote Units redefine the function of the Scroll Lock key for system
commands.
Press the Scroll Lock key to reset the keyboard and mouse. You may need to do this if a hot-
plugged keyboard or mouse does not initialize correctly.
You can restore normal Scroll Lock activity by setting switch 4 on the SW1 DIP switch block
to OFF (see Figure 13). If you do this, and then need to reset a console’s keyboard and
mouse, you will need to re-power the Remote Unit. This also disables Private Mode operation
in dual access systems (see page 35).
Power Mouse K’board Video
RJ45 Brightness Focus
DIP Switch settings
OFF
ON
Private Mode Video Disable
YES
NO
SUN versions: disables private mode
Inactivity Timeout Period
15s
2s
Console Switch
Keyboard or Mouse
Keyboard Only
Scroll Lock Function
Normal
Private
Mode/
PS/2 versions only
K’board/Mouse
Reset
SUN versions - not used
Mouse
Recovery
Figure 13
Remote Unit DIP switches:
Switches 1, 2 and 3 control the implementation of Private
mode and dual access functions on the Local Unit (see page
35).
SW1 DIP
switches