63
APPENDIX B: Cable Test Pass/Fail Limits
B.2 Coaxial Cables
The following charts show the Pass/Fail limits used
by the Scan-LAN 80 while testing coaxial cables.
ThinNet Pass/Fail Limits
ThinNet Test Limits
Length
Length < 185 meters
Background Noise
Background Noise < 400 mV
Characteristic Impedance
50±12 ohms
Termination Resistance
50±20 ohms
Thicknet Pass/Fail Limits
Thicknet Test Limits
Length
Length < 500 meters
Background Noise
Background Noise < 400 mV
Characteristic Impedance
50±12 ohms
Termination Resistance
50±15 ohms