CHAPTER 3: Configuration
Switch S2-8: V.54 Loopback Test Enable
This switch enables or disables V.54 looping in the Async/Sync Industrial Line
Driver.
S2-8
Setting
Off
V.54 Normal Operation Enabled
On
V.54 Testing Disabled
3.4 Configuration Switch Set S3
The DIP switches on S3 set the anti-stream control, timing mode, topology, local
loopback enable, remote loopback enable, and input impedance levels for the
Async/Sync Industrial Line Driver. Factory-default positions are shown in the table
below.
Table 3-4. S3 switches
Position
Function
Factory Default
S3-1
Input Impedance
On
S3-2
Input Impedance
Off
200 ohms
S3-3
Timing Mode
Off
S3-4
Topology
On
Point-to-point
S3-5
Local Loopback
Off
Disabled
S3-6
Remote Loopback
Off
Disabled
S3-7
Anti-Stream Control
Off
S3-8
Anti-Stream Control
Off
Disabled