Chapter 5: Configuration
Table 5-1 (continued). AT commands.
y < command
command name > x
Description
N
Advanced Spectrum
Analyzer
The Advanced Spectrum Analyzer feature provides for a very detailed analysis
of a particular area of the radio frequency spectrum within which the
MDR100A-R5 or MDR112A-R5 operates.
The specific start (of scan) and stop frequencies, along with step (increment)
size and dwell (on frequency) time are user-definable.
Following is the format for the ATN command:
In Command Mode
ATN F
start
F
stop
S D[Enter]
where
F
start
= start frequency in MHz (including 0–6 decimal places)
F
stop
= stop frequency in MHz (including 0–6 decimal places)
S = step increment in kHz (from 1–1000)
D = dwell time in ms (from 1–1000)
Example:
ATN 905.250 908.500750 25 100
NOTE: Be sure to enter spaces as shown in the format detailed above.
O
Online Mode
When the modem completes tasks in Command Mode, invoking this
command will place the modem back “online” (into Data Mode).
&Fn
Load Factory Default
Configuration
See Chapter 4 for detailed information on the various factory default options.
Values
1 PMP Master
2 PMP Slave
3 PMP Repeater
4 Slow Mode PMP Master
5 Slow Mode PMP Slave
6 PTP Master
7 PTP Slave
8 Slow Mode PTP Master
9 Slow Mode PTP Slave
NOTES:
Slow Mode is an option for the MDR100A-R5 or MDR112A-R5.
If the module being configured does not support Slow Mode, do not load a Slow Mode factory default configuration.