26
SECURE RACK MODEM
If the modem does not respond, check the following:
• Modem Communication Parameters: The Secure Rack Modem’s internal
modem and your remote communications program must be set to use the
same communication parameters. You can select the default modem
communication parameters using setup switches #1 through #8 (factory setting
is 9600 bps, no parity, 8 data bits, one stop bit).
5.2 The General Parameters Menu
Use the menu shown in Figure 5-2 to set the real-time clock, and select the system
password, site ID, and other general parameters. To access the General
Parameters menu, activate the modem’s Command mode as described in
Section 5.1
, then type
/G
and press
[Enter]
.
Figure 5-2. The General Parameters menu.
To change the setting for any item in this menu, key in the number for the desired
item, press
[Enter]
, then follow the instructions in the submenu. The General
Parameters menu includes the following items:
1. System Password: This password protects modem access to the Command
mode. When a caller connects to the modem, it sends a password prompt. If
the system password is entered, the caller will then be granted access to the
Secure Rack Modem’s Command mode.
GENERAL PARAMETERS
1. System Password:
SUPER
2. System Dial Back #:
(undefined)
3. Site ID:
(undefined)
4. Real Time Clock:
Tue 06/13/2000 11:25:26
5. Console Port Communication:
9600, N, 8, 1
6. Command Echo:
On
7. No Activity Timeout:
5 Min
8. Password Attempts:
3
9. Password on Dial Back:
Off
10. Security Mode:
On
11. Audit Log Options:
All
12. Dial Back Attempts:
1
13. Dial Back Delay:
30 Sec
Enter Selection,
Press <Esc> to Abort…