CHAPTER 2: AT Commands
13
Command:
&Y
n
Select Profile for Hard Reset
Values:
n
= 0 or 1
Default:
None
Description:
&Y0
Select profile 0 to be loaded on power-up.
&Y1
Select profile 1 to be loaded on power-up.
NOTE
See also the &W and Z commands.
Command:
&Z
n=x
Store Telephone Number
Values:
n
= 0–3 (with callback security disabled)
&Z3 is the phone memory location for leased-line dial backup number.
n
= 0–29 (with callback security enabled—for a future release)
x
= Stored telephone number
Default:
None
Description:
Stores telephone dial string
x
in memory location.
&Z3 is the phone memory location for leased-line dial backup number.
Dial the stored number using the ATDS=
n
command.
NOTE
See also the #CBS
n
command.
Command:
%C
n
Data Compression Control
Values:
n
= 0, 1, 2, or 3
Default:
3
Description:
Enables or disables data compression negotiation. The modem can
only perform data compression on an error-corrected link.
%C0
Disables data compression.
%C1
Enables MNP 5 data compression negotiation.
%C2
Enables V.42bis data compression negotiation.
%C3
Enables both V.42bis and MNP 5 data compression negotiation.
NOTE
This command controls both V.42bis and MNP 5 data compression, whereas the &E14
and &E15 commands control only V.42bis data compression. The command in effect is
the one last entered.
Command:
%E
n
Line Quality Monitor
Values:
n
= 0, 1, or 2
Default:
2
Description:
Controls whether or not the modem will automatically monitor the line
quality and request a retrain (%E1) or fallback to a lower speed when
line quality is insufficient and fall forward to a faster speed when line
quality is sufficient (%E2).
%E0
Disables line quality monitor and auto-retrain.
%E1
Enables line quality monitor and auto-retrain.
%E2
Enables line quality monitor and fallback/fall forward.
Summary of Contents for MD1650A-JP