41
4. Press
Enter
, and on the following screen type the default username
admin
.
Leave the password field blank since there is no default value. Press
Enter
to
proceed.
5. Select the CLI user interface option by pressing the associated number key or
using the
Tab
key and pressing
Enter
. A command prompt appears.
NOTE
Type “?” or “help” to view the entire commands and explanations list.
5.3.2 C
OMMAND
D
EFINITIONS
backup:
Use this command to save configuration settings to file.
exit:
Type
exit
or
logout
and press
Enter
to quit the program.
help:
Access the help commands list.
ping:
Type
ping
, then a space, then the IP address of the device to send a test
signal. If a response is received, then the device is connected. To view a full list of
ping options, type
ping
and press
Enter
.
reset:
Type
reset config
and press
Enter
to load factory-default settings, or type
reset system
and press
Enter
to restart the system.
set:
To configure the management console, type the commands below, followed by
the
Enter
key.
NOTE
Separate each command line port with a space.
set admin:
Follow the prompts to change the username and password.
set cfg:
Use this command to set new addresses. Use
set eth0 ip
(new IP
address),
network mask
(new network mask), or
gateway
(new gateway).
set idle:
Set the automatic logout time (in seconds) when the program or
communication is idle.
set xfer:
This command sets RS-232 configuration and data communication
parameters. The command syntax is as follows.
set xfer [arg_1 data_1][arg_2 data_2]
[arg_n data_n]
CHAPTER 5: Configuration