76
4-, 8-, AND 16-PORT SERVSWITCH EC SERIES IP KVM SWITCH
Problem:
I cannot select a computer connected to a slave.
Solution:
Make sure that the slave’s console port is connected to one of the
master’s PC ports. Only Ports PC 1 to PC 8 can be connected to slaves, even if the
master switch has 16 PC ports.
Problem:
Keyboard strokes are shifted.
Solution:
Press both
Shift
keys.
Problem:
A certificate warning is shown while connecting via HTTPS.
Solution:
It is normal for a warning dialog to be shown when connecting via
HTTPS. The SSL certificate the ServSwitch uses is created when the unit is first
produced. It does not contain the correct hostname (subject name) because you
can change the hostname as required. For more details, refer to
Appendix C
.
Problem:
Windows XP doesn't awake from standby mode.
Solution:
This is possibly a Windows XP problem. Try not to move the mouse while
XP goes into standby mode.
Problem:
The terminal connection to the ServSwitch for initial configuration
cannot be established.
Solution:
Check that the null-modem cable connected to DCE serial port on the
ServSwitch and terminal software is set to the following line parameters:
Connection speed: 115200 bps
No. of bits: 8
Parity: None
Stop bits: 1
Flow Control: None
Summary of Contents for KV9304A