CHAPTER 3: INSTALLATION
3.1 REQUIREMENTS FOR INSTALLING THE EXTENDER
To complete the installation, you will also require the following items that are not included with this system:
USB compatible computer (host computer) with a USB compliant operating system
USB compatible device(s)
OM3 fiber optic cabling
3.2 FIBER OPTIC CABLING GUIDELINES
The Local and Remote Extenders are interconnected by fiber optic cabling. Duplex multimode fiber cabling is required for the extenders
for extending up to 656 feet (200 meters) using 50/125-μm OM3 grade cable. The cabling subsystem must provide a duplex connection
with crossover, and must be terminated with Duplex LC connectors at both ends.
Host
USB Cable
Optional
Network
Connections
Optional
Network
Connections
USB Devices
Local Extender
Remote Extender
USB 3-2-1
Up to 656 ft. (200 m) over MMF
LAN
IP Control
FIGURE 3-1. TYPICAL INSTALLATION
3.3 PREPARING YOUR SITE
Before installing the USB 3.1 Extender, you will need to prepare your site:
1. Place the computer where desired and set it up.
2. Locate your USB device(s) within the cable-length of the computer. If not, adjust the location of your device(s) and/or computer
accordingly.
3. If you are using surface cabling, the USB 3.1 Extender supports a maximum distance of 656 feet (200 meters) over OM3 multimode
fiber.
4. If using premise cabling, ensure compatible fiber optic cabling is installed between the two locations and does not to exceed the
specified distance.
3.4 INSTALLING THE LOCAL EXTENDER
1. Place the Local Extender near the computer.
2. Assemble the 24-V, 1-A power adapter and country-specific power cord together and connect them into a suitable AC outlet.
3. Connect the supplied USB 3.1 Gen cable between the Local Extender host port and a USB 3 port on the host computer.