9
USB CHARGING PORT
The USB charging port is under the same protective cover as the 12 volt DC
outlet. Refer to the Features section to locate.
1. Press the AC/USB power power button to turn the USB port on. A beep
will sound and the backlit LCD screen will continuously display the
following:
The “5V USB” icon indicates that the USB port is ready to use.
2. Plug the USB-powered device into the USB power port and operate
normally.
The USB power port remains on until the AC/USB Power button is pressed
again to turn it off. Make sure the USB port is turned off when the unit is
being recharged or stored.
IMPORTANT NOTES:
When the USB Port is in use, the unit will monitor for the following USB
fault conditions on the USB Port: low battery voltage fault, overload and
short circuit.
If a low internal battery voltage fault condition exists, the USB port and AC
Power Outlets will shut down automatically and the backlit LCD screen will
display the following until the fault is corrected:
The Digital Display will show the Battery Voltage Indicator; the EMPTY
Battery Status Icon and Fault Icon on the LCD Screen will flash.
If overload or short circuit fault condition exists, the USB port and AC Power
Outlets will shut down automatically and the backlit LCD screen will display
the following until the fault is corrected:
The Battery Status Icon will light solid; the “AC” and USB icon on the Digital
Display and the Fault Icon on the LCD Screen will flash.
Should any of the above fault conditions occur:
• Disconnect the USB-powered device and press the AC/USB Power Button
again to turn it off immediately.
• Allow the unit to cool down for several minutes before attempting to use
the USB port again.
• If a fault occurs again, make sure that the total draw of the USB device
plugged into the USB Port does not exceed 2A.
• If individual USB device is within specifications and the fault occurs, have
the USB device checked for malfunction and do not continue to use it
with the USB port.
Periodically check the unit’s Battery Status on the backlit LCD screen. Four
solid bars in the battery icon indicates a full battery. When the battery level
is nearly empty with only one solid bar or completely empty with 4 empty
bars, the unit must be recharged at this time or the unit’s built-in low
voltage protection will activate. The empty Battery Status Icon will flash for
a short period of time before automatic shut down.
Note:
This unit’s USB power port does not support data communication. It only provides 5V
DC/2A power to an external USB-powered device.
PORTABLE COMPRESSOR
The built-in 12 volt DC compressor is the ultimate compressor for vehicle
tires, trailer tires and recreational inflatables. A nozzle adaptor is supplied
that screws onto the end of the Sure Fit
®
nozzle at the free end of the
compressor hose. The compressor hose with tire fitting is stored in the
storage compartment. Refer to the “Features” illustration for locations of
compressor hose. The Compressor Power Button and Increase (+) and
Decrease (–) Compressor Pressure Control Buttons are located on the
control panel on the front of the unit.
Before proceeding, check the unit’s Battery Status on the LCD screen. Four
solid bars in the battery icon indicates a full battery. When the battery level
is nearly empty with only one solid bar, the unit MUST be recharged before
use or the unit’s built-in low voltage protection will activate. The empty
Battery Status Icon will flash for a short period of time before automatic
shut down.
The compressor is capable of inflating up to 120 pounds per square inch
(PSI) pressure. The compressor can operate long enough to fill up to 3
average sized tires before the battery must be recharged. Return hose to
the storage compartment after use.
IMPORTANT:
Make sure the Jump Starter Power Switch has been turned
off before attempting to use the unit as a Compressor.
WARNING –
TO REDUCE THE RISK OF SERIOUS INJURY OR
PROPERTY DAMAGE:
Follow all safety instructions found in the “Specific
Safety Instructions for Compressors” section of this instruction manual.
CAUTION –
TO REDUCE THE RISK OF SERIOUS INJURY OR
PROPERTY DAMAGE:
When the compressor is operated at a low PSI, the
unit may start slowly and gradually rev up. When the compressor is
operated at higher PSIs, the unit may operate normally for several minutes,
then rev down for a few minutes before returning to normal operation. This
feature protects the unit from overheating during normal use. In any event,
do not operate compressor continuously for longer than 10 minutes, as it
may overheat. This could damage the compressor. If the compressor must
be operated for longer periods: every 10 minutes press the Compressor
Power Button to turn the compressor off, then restart after a cooling down
period of approximately 30 minutes. In any event, the compressor will
automatically shut down after operating continuously for 10 minutes.
Inflating Tires or Products With Valve Stems
1. Screw the Sure Fit
®
nozzle onto the valve stem. Do not overtighten.
2. Press the Compressor Power Button. A beep will sound and the backlit
LCD screen will display the following:
The Compressor Icon will light and the digital display will alternately
show the flashing pre-set PSI value (that was last set by the
compressor pressure control buttons) and the current pressure of the
item being inflated (which will light solid).
3. Press the “+” and “–” Pressure Control Buttons to set the desired
pressure from a range pre-set values (between 3 and 120), which will
display on the backlit LCD screen. The unit will sound a beep with
each press of the buttons (holding the button speeds up the upward
or downward value selection). Once the desired pressure has been
entered, release the button and the flashing digital display will show the
new selected pressure, as follows:
4. Press the Compressor Power Button once more to begin inflating. The
Compressor Icon will flash and the digital display will only show the
current pressure value (which will light solid) to indicate the compressor
is activated. Monitor the pressure on the LCD screen.
IMPORTANT NOTE:
To interrupt during inflation, press the Compressor
Power Button again.
5. When desired pre-set pressure is reached, the compressor will
automatically stop.
6. Press the Compressor Power Button again to turn off the unit.
7. Unscrew and remove the Sure Fit
®
nozzle from the valve stem.
8. Allow the unit to cool, then recharge before storing away.
9. Store the compressor hose and Sure Fit
®
nozzle in storage
compartment.
Inflating Other Inflatables Without Valve Stems
Inflation of other items requires use of the nozzle adapter.
1. Screw the nozzle adapter into the Sure Fit
®
nozzle. Do not overtighten.
2. Insert the nozzle adapter into item to be inflated.
3. Follow steps 2 through 4 of the “Inflating Tires or Products With Valve
Stems” section.
IMPORTANT:
Small items such as volleyballs, footballs, etc. inflate very
rapidly. Keep this in mind when setting pressure. Take extra care not
to over-inflate.
Summary of Contents for PPRH5B