SAFETY INFORMATION
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current
Detection and Interruption) power cord that is required by UL. This
power supply cord contains state-of-the-art electronics that sense
leakage current. If the cord is damaged and leakage occurs, power will
be disconnected from the unit.
The test and reset buttons on the LCDI Plug are used to check if the
plug is functioning properly.
WARNING:
Test LCDI before each use.
To test the plug:
1. Plug power cord into a grounded 3 prong outlet.
2. Press RESET (on some units a green light will turn on).
3. Press the TEST button, the circuit should trip and cut all power to the air
conditioner(on some units green light may turn off).
4. Press the RESET button for use. You will hear a click and the A/C is ready
for use.
5. The power supply cord must be replaced if it fails to trip when the TEST
button is pressed and the unit fails to reset.
NOTES:
• Do not use this device to turn the unit on or off.
• Always make sure the reset button is pushed in for correct operation
• WARNING:
• The power supply cord must be replaced if it
fails to reset when either the test button is
pushed, or it cannot be reset.
• If power supply cord is damaged, it cannot
be repaired.
• It must be replaced by one obtained from
the product manufacturer.
WARNING – RISK OF FIRE
• It is important the plug fits tightly into the wall outlet.
• If the plug does not fit securely and appears loose, it should not be used.
• Have a licensed electrician replace the receptacle.