BKI Fry Warmer
Maintenance
11
Troubleshooting
Refer to the table below for troubleshooting information.
Problem Cause
Possible
Solution
Package Holding Area is
not holding heat
Ceramic heating
element failure
Contact an authorized BKI service agent for
corrective action.
Noisy fan
Fan blade is dirty or fan
bearings are failing
Contact an authorized BKI service agent for
corrective action.
Package Holding Area is
not heating and perforated
pan is not heating
No power to unit.
Make sure that the circuit breaker and switch at the
power supply are supplying power to the unit. If
problem persists, contact licensed electrician.
Pilot light on Hood
Illuminated
Package Holding Area is
heating and the perforated
pan is not heating
Fan has overheated and
cut off
Or
Heating coil has failed
Wipe the dust from the air intake louvers to allow
proper airflow and prevent fan overheating. Also
check exhaust grid for blockage and clean if
necessary. Turn the power switch off. Wait 60
seconds. Turn the power switch back on.
Contact an authorized BKI service agent for
corrective action.