Operating instructions eS10
IXNET dialogs
38034911005 en
69
7
Possible errors
3002
Weighing function not executable
Requesting device ID and device information
In order to receive general information of the device, the
GV05
command can be run as fol-
lows:
Command
Response
I?GV05|LX02
I!GV05|GT12|BIZERBA eS10|GT13|602.82.410.06|GL19|24022014|
GT08|34|GV06|GW01|1|GW09|1|kg;-3;12000|GD0A|kg;-3;1|LX02|
LX02
GV05 device information
Fixed return values
GT12
: Device family
GT13
: Device software version
GL19
: Device release date (format: ddmmyy)
GT08
: System number
Subordinate commands from GV06:
GW01
: Scale number
GW09
: Active scale
GD09
: Weighing range
GD0A
: Digital increment of scale
Text block (additional characters) (weighing module)
Read text block
Command
Response
I?GV02|GW04|1|LX02
I!GV02|GW04|1|GT02|ABC|LX02
Write text block
Command
Response
I!GV02|GW04|1|GT02|ABC|LX02
I!LW00|1538
Command
Description
GV02
Read/write text block
GW04
Storage number of text block
GT02
Text block