14
English
Parallel/USB Interface Specification
Dip Switch Set 1 Functions
SW FUNCTION
ON
OFF
DEFAULT
1
Auto Line Feed
Always
enabled
Always
disabled
OFF
2 Reserved
-
-
OFF
3 Reserved
-
-
OFF
4 Reserved
-
-
OFF
5 Reserved
-
-
OFF
6 Reserved
-
-
OFF
7 Reserved
-
-
OFF
8 Reserved
-
-
OFF
Dip Switch Set 2 Functions
SW FUNCTION
ON
OFF
DEFAULT
1 Emulation
STAR
EPSON
OFF
2 Reserved
-
-
OFF
3 Reserved
-
-
OFF
4
Busy
Condition
•Receive Buffer Full •Offline
•Receive Buffer Full
OFF
5
OFF
6
Select
Print Density
Refer to the Following Table
OFF
7
Near End
Sensor Status
Disable Enable
OFF
8 Reserved
-
-
OFF
Print Density
Print Density
SW - 5
SW – 6
1 ( Light )
ON
ON
2 OFF
OFF
3 ON
OFF
4 ( Dark )
OFF
ON
※
Auto Cutter Enable / Disable selection
Dip Switch Set 2
SW 2
ON
SW 3
ON
Auto Cutter Disabled
Application
Ignores Auto Cutter error for continuous printing
15
English
Chapter 2. Hexadecimal Dumping
This feature allows experienced users to see exactly what data is coming to the printer.
This can be useful in finding software problems. When you turn on the hexadecimal dump
function, the printer prints all commands and data in hexadecimal format along with a
guide section to help you find specific commands.
To use the hexadecimal dump function, follow these steps:
1.
After you make sure that the printer is off, open the cover.
2.
Turn on the printer, while holding down the FEED button.
3.
Close the cover, then the printer enters the hexadecimal dump mode.
4.
Run any software program that sends data to the printer. The printer will print all the
codes it receives in a two-column format. The first column contains the hexadecimal
codes and the second column gives the ASCII characters that corresponds to the
codes.
1B 21 00 1B 26 02 40 40 40 40
. ! . . & . @ @ @ @
02 0D 1B 44 0A 14 1E 28 28 28
. . . D . . . . ( ( (
00 01 0A 41 0D 42 0A 43 43 43
. . . A . B . C C C
z
A period (.) is printed for each code that has no ASCII equivalent.
z
During the hex dump, all commands except
DLE EOT
and
DLE ENQ
are
disabled.
5.
When the printing finishes, turn off the printer.
6.
Turn on the printer and then the hexadecimal mode is off.
Summary of Contents for SRP-350 PlusA
Page 11: ...18 English Page 2 PC850 Multilingual 19 English Page 3 PC860 Portuguese ...
Page 12: ...20 English Page 4 PC 863 Canadian French 21 English Page 5 PC 865 Nordic ...
Page 13: ...22 English Page 19 PC858 Euro 23 English Page 255 Space Page ...
Page 41: ...19 French Page 3 PC860 Portuguais 20 French Page 4 PC 863 Canadien Français ...
Page 42: ...21 French Page 5 PC 865 Nordique 22 French Page 19 PC 858 Euro ...
Page 43: ...23 French Page 255 Page d espace 24 French Jeu de caractères internationaux ...
Page 59: ... 4 Spanish Página 2 PC850 Multilingüe 4 Spanish Página 3 PC860 Portugués ...
Page 60: ... 53 Spanish Página 4 PC 863 Francés Canadiense 54 Spanish Página 5 PC 865 Nórdico ...
Page 61: ... 55 Spanish Página 19 PC 858 Euro 56 Spanish Página 255 Página Espacio ...
Page 86: ...17 Página 2 PC850 Multilingue Portuguese ...
Page 87: ...18 Página 3 PC860 Português Portuguese ...
Page 88: ...19 Página 4 PC 863 Francês Canadá Portuguese ...
Page 89: ...20 Página 5 PC 865 Nórdico Portuguese ...
Page 90: ...21 Página 19 PC 858 Euro Portuguese ...
Page 91: ...22 Página 255 Página Espaços Portuguese ...
Page 92: ...23 Conjunto de Caracteres Internacional Portuguese ...