Industrial Cellular IP Modem 

TD210 Series User Guide 

 

 

 

 

Summary of Contents for TD210 Series

Page 1: ...Addr Unit 704 No A3 Building Tel 86 592 6211770 3rd Software Park Xiamen China 361000 Fax 86 592 6211727 www bivocom com sales bivocom com 1 Industrial Cellular IP Modem TD210 Series User Guide...

Page 2: ...ions and information in this document are subject to change without any notice and BIVOCOM reserves the right to improve and change this user guide at any time Users should take full responsibility fo...

Page 3: ...is compatible with below models Model Description TD210 G Industrial GPRS IP Modem TD210 W Industrial WCDMA IP Modem TD210 LF Industrial LTE WCDMA IP Modem Summary of Changes Date Version Notes Edito...

Page 4: ...on 9 3 3 1 SIM UIM Card 9 3 2 2 Cellular Antenna 9 3 2 3 Terminal Block Power Cable and Console Cable 10 3 3 Power Supply 11 3 4 LED Indicators 11 4 Configuration 12 4 1 Getting started 12 4 2 Serial...

Page 5: ...om Register String 23 4 4 7 Custom Heartbeat String 23 4 4 8 Transfer Meaning 23 4 4 9 TCP MTU 23 4 4 10 Multi Center Reconnect Interval 24 4 4 11 Reconnect 24 4 4 12 ECHO Heartbeat Interval 24 4 4 13...

Page 6: ...f industrial wireless IP Modem Also called DTU Data Transfer Unit designed to fully meet the needs of industrial standards and industrial users It adopts high powered industrial 32 bits CPU multi laye...

Page 7: ...and transmission and has been used for industrial remote monitor and control Typical application as below 3 Getting Started WARNING Please make sure the device is powered off before you install and c...

Page 8: ...704 No A3 Building Tel 86 592 6211770 3rd Software Park Xiamen China 361000 Fax 86 592 6211727 www bivocom com sales bivocom com 8 3 2 Dimensions There are 3 holes for installation at each side of TD2...

Page 9: ...adapter Make sure your IP Modem is powered off then use a needle object such as a pen to push the button near the SIM UIM card holder it will flick out immediately Put the SIM UIM card to card holder...

Page 10: ...TTL TX 5 IO3 GPIO able to check dry contact signal and 3 3 V switch signal output 3 3V switch signal Reserved RS232 DCD 6 IO4 GPIO able to check dry contact signal and 3 3 V switch signal output 3 3V...

Page 11: ...y then plug the power supply to power outlet TD210 adopts advanced power technology to improve the stability and adapt to complex external environment You can use Bivocom standard power adapter 12VDC...

Page 12: ...download the config tool like below http www bivocom com index php m content c index a show catid 12 id 22 Note The config tool only support Windows OS IOS is not supported yet 4 2 Serial port config...

Page 13: ...Addr Unit 704 No A3 Building Tel 86 592 6211770 3rd Software Park Xiamen China 361000 Fax 86 592 6211727 www bivocom com sales bivocom com 13 Figure 1 Figure 2...

Page 14: ...com 14 Figure 3 Below are quick instructions of Operations on the config tool but you can go to next step 4 3 Basic setting if you re familiar with those parameters 4 2 1 Save Click to save the param...

Page 15: ...e version info of TD210 4 2 5 Signal Value Check the signal strength of TD210 4 2 6 Factory Setting TD210 returns to factory setting 4 2 7 Restart Restart TD210 4 2 8 Save Config Save configuration of...

Page 16: ...ivocom com 16 4 3 Basic Setting Figure 4 4 3 1 Device ID To identify the TD210 and for device management if you have many TD210 connected to server please make sure all the ID are different 4 3 2 SIM...

Page 17: ...ioned above it is always online for SMS function 4 3 4 Debug Level There are 3 levels to choose from the drop down menu as below 2 All logs output through RS232 RS485 1 Part of important logs output t...

Page 18: ...wer the value 20ms for 115200 baud rate 50ms for 9600 baud rate and 200ms for 1200 baud rate 4 3 8 Trigger Settings 1 Trigger Type AUTO Always online SMSD SMS trigger mode sending specific SMS to trig...

Page 19: ...your code is 123456 you can trigger TD210 by sending SMS text DAIL123456 4 Data Trigger On Password You can set up trigger data in the blank once the trigger mode is DATA and MIXD and TD210 receives t...

Page 20: ...CUDP HUDP TCPSVR and UDPSVR Custom register string and heartbeat packet is required when work mode is CTCP and CUDP TD210 will act as a TCP client when choose FTCP HTCP and CTCP but the register stri...

Page 21: ...ta center TD210 will connect to main center once it couldn t connect to backup center it will continue to connect to main center till it s connected 2 5 means TD210 supports multi centers and all the...

Page 22: ...xamples of APN Username Password and call center of Chinese mobile carriers Model APN Username Password Call Center TD210 G Cmnet China Mobile Uninet China Unicom Null 99 1 TD210 C Null card 777 TD210...

Page 23: ...r String You can configure it when network word mode is configure as CTCP and CUDP but you can also choose not to configure it which means register string won t be sent Note the length of register str...

Page 24: ...a flow when Reconnect Time Interval enabled TD210 will try to reconnect data center and if Connect Retry Times exceed the value you set while TD210 is still unable to reconnect to data center TD210 wi...

Page 25: ...ll phone length shall not exceed 15 numbers When TD210 receives data from serial port while if the network disconnects and data will be sent to preset cell phone through SMS SMS data backup 4 5 2 SMS...

Page 26: ...Receiving Enable Disable When TD210 receives SMS you can choose whether to transfer the cell phone number and SMS to serial port or not 4 6 MODBUS Setting 4 6 1 MODBUS Work Mode MODBUS Disable Network...

Page 27: ...RTU mode analog work mode is normally set as Collect Once TD210 will collect the data through corresponding terminal port after receiving MODBUS command 2 1st Digital Work Mode 2nd Digital Work Mode a...

Page 28: ...d Software Park Xiamen China 361000 Fax 86 592 6211727 www bivocom com sales bivocom com 28 4 5 Power on the TD210 then device will start to upgrade the firmware as below 4 6 After firmware upgrading...

Page 29: ...1770 3rd Software Park Xiamen China 361000 Fax 86 592 6211727 www bivocom com sales bivocom com 29 4 7 Then use the Config Tool to enter into the configuration status set up the device to factory sett...

Page 30: ...e to set only not command Description AT Command Parameter Debug Level AT DEBUG XX XX 0 No logs 1 Simple logs 2 Detailed logs Baud Rate AT IPR XX XX from 300 to 115200 Data bit stop bit and Parity AT...

Page 31: ...er DNS Server AT DNSSVR XX XX Main Center DNS Server Backup Center DNS Server AT DNSSV2 XX XX Backup Center DNS Server 2nd Center DNS Server AT DNSSVR1 XX XX 2nd Center DNS Server 3rd Center DNS Serve...

Page 32: ...end Phone No AT PHONE4 XX XX Use comma for multi phone number SMS Send Type AT HEXSMS XX XX 0 Normal SMS 1 HEX SMS SMS Send Backup AT OPENSMSBCKP XX XX 0 NO Backup 1 YES to Backup Display SMS Receivin...

Page 33: ...nd locked correctly and antenna is fasten 2 Check the IP address and port of server in the configuration tool is correct 3 Check whether the server is working 4 Check if the SIM is out of service char...