DB-309-3
14
2.3
Safety references especially for the use in
zones 1 and 2
DANGER
Risk of explosion due to hot surfaces!
The surface temperature of 130°C must not be
exceeded at any point!
DANGER
Risk of explosion due to spark formation!
Avoid ignition sources and open fire!
Use only low-sparking tools!
Mobile phones must be switched off!
DANGER
Risk of explosion due to dust and oil!
Avoid all contamination!
Clean the whole system as needed but at least
every six months.
DANGER
Risk of explosion due to the discharge of elec-
trostatic charges!
Use only devices suitable for potentially explos-
ive atmospheres and assess and list them in the
explosion protection document of the end user!
Do not operate the devices in the vicinity of pro-
cesses producing high charges (e.g. mechanical
separation processes)!
Take measures against electrostatic charging of
non-metallic components, tools, auxiliaries and
clothing!
Wear, for example, suitable antistatic clothing,
use low-sparking tools, a moist cloth for clean-
ing, and perform additional earthing of conduct-
ive parts.
In addition to the EU Explosion Protection Directive
2014/34/EU (ATEX 114) and the safety regulations in-
dicated in the standard Operating Instructions, the spe-
cific regulations EN 60079, 80079-36, -37 and the EU
Directive 1999/92/EC (ATEX 137) must be adhered to!
WARNUNG
Gefahr durch elektrostatische Entladungen!
Siehe Betriebsanleitung!
Danger due to electrostatic discharge!
See operating instructions!
37802403
WARNING
Fig. 1: Adhesive label on the compressor
The following components can become electrostatically
charged:
• Name plate (5% of aluminium content and additional
protective laminate made of PTFE)
• Other adhesive labels (oil level, hot surfaces, etc.)
• Vibration dampers
• Varnish layer
• Other plastic surfaces, e.g. INT 250Ex
The following standards have been applied:
• EN1127-1: 2019
• EN ISO80079-36:2016
• DIN EN80079-37:2016