BioSure PROFESSIONAL EOS7190-P Owner'S Manual Download Page 17

BioSure Professional is a division of Biotek Environmental Science Ltd. (BES). BES is a global leading electrolytic product 
manufacturer with pioneering ozone application technology and currently holds many exclusive patents for its 
electrolytic ozone generators and products worldwide.

WARRANTY DESCRIPTION

Equipment manufactured by Biotek Environmental Science Ltd. has been constructed of the finest materials available and 
manufactured to high quality standards. When installed in accordance with manufacturer's recommendations, and under 
normal use and service, new BioSure products are warranted to be free of defects due to poor materials or workmanship for the 
period of time listed below (following the date of purchase):
- Main Device:

2 Years Parts Only Replacement (excluding wear and consumable parts)

- Consumable Parts:

If the product fails during the warranty period, please show your proof of purchase to your dealer and ask for repairs. If the 
product is not in the place of purchase for on-site maintenance or the product needs to be shipped, the actual costs incurred, 
such as transportation fees, may be charged.

Exclusions: Certain BES parts that are expendable by nature and that need to be replaced frequently may not be covered. 

BES is not liable under these warranties for repairs or damages due to improper operation, attempted repairs or installation 

by unauthorized persons, alterations, abuse, fire, flood,

or acts of nature. Additionally, this warranty may be voided in the case of:

- Failure to follow BES (and BioSure Professional) instructions for use, care, or maintenance

- Removal, alteration, or defacing of the BES-affixed serial number and other labels

- Mechanical damage

- Use of fluids other than clean, potable water

This warranty is conditional upon BES receiving notice of any defect subject to this warranty within thirty (30) days of its original 

discovery by the Buyer. For service or warranty questions, contact the BES service department or BES authorized dealer nearby.

16

9.SPECIFICATIONS

Product Name
Model
Water Supply for Humidification

Water Supply for the EOG
Power
Ambient Temp

Space Sanitizer System Plus
EOS7190-P
Pure water or distilled water (TDS < 1ppm or EC < 2μS/cm)

Pure water or distilled water (TDS < 1ppm or EC < 2μS/cm)

AC 100 - 240V, 50 - 60Hz, 33W
Room temperature 5 - 35℃
W230 x D127 x H300(mm)
For use on a hard, level, and stable surface or wall mount only
2.5kg(Unfilled)

Dimensions 

and Weight

Dimensions
Location Requirements

Weight

【Waste Disposal】

When disposing of this product, follow the instructions of the local government (local regulations) for disposal.

【Consumable Parts】  

The models of consumables are as follows.

※ For purchasing consumables and related inquiries, please contact your BioSure distributor.       

C12011000303-80

Electrolytic Ozone Generator (EOG)

A71902007041

HEPA Filter

B71902007010

DI Water Filter

hour usage life-span monitored by the unit, or 1 year from the date of installation, 

the date of installation, whichever comes first. Parts only. The limited warranty of BES only covers ozone generators that 
fail due to manufacturing defects, but not those are depleted due to normal use.

                           2. DI water filter & HEPA filter - Except for goods due to manufacturing defects or poor quality, it's not guaranteed or returned

after unpacking or use.

1. Electrolytic ozone generator - within the 

Summary of Contents for PROFESSIONAL EOS7190-P

Page 1: ...es 5 Preparation Before Use 6 How to Use 7 Maintenance 8 Troubleshooting 9 Speci cations Warranty Description P2 P3 P5 P6 P7 P8 P8 P9 P10 P11 P12 P14 P15 P1 P16 Table of Contents Space Sanitizer Syste...

Page 2: ...EOS7190 P V2 1 EN...

Page 3: ...rying to repair or install 3 The labor costs derived from the normal maintenance calibration or general adjustment speci ed in this manual 4 Maintenance or damage caused by alteration abuse re ood or...

Page 4: ...cause personal injury 2 or property damage 3 if not avoided CAUTION indicates a dangerous situation that may cause personal injury 2 or property damage 3 if not avoided Do not use this product in plac...

Page 5: ...product The input power of the power adapter of this product is AC100 240V Do not use loose sockets Otherwise it may cause re electric shock or short circuit Do not use a damaged power cord or power...

Page 6: ...e do not use electrical electronic contact cleaners in addition to damaging to the appearance these chemicals may also melt the parts Do not rinse the main device with water If the main unit is dirty...

Page 7: ...REFILLING SMART SENSOR 12 9 11 10 1 3 4 5 6 7 2 8 FAN SPEED HUMIDIFIER GENERATOR TIMER LEVEL Mode Humidi cation Start Stop Timing Air Volume Water Replenishment Captions 4 1 Fault indicator 2 Standby...

Page 8: ...g to the Food and Drug Administration FDA According the Occupational Safety and Health Administration OSHA the concentration standard for continuous exposure to ozone is limited to exposure for 8 hour...

Page 9: ...sing please hang the product on the wall or place it on a rm and at table or shelf When ozone is generated the blue operation indicator on the top of the unit will be lit This light cannot be turned o...

Page 10: ...Water shut o valve Plug 6 Press the GENERATOR button to start the water pump The device will beep to start replenishing pure water At this time the REFILLING indicator will light up 7 After the water...

Page 11: ...he STANDBY indicator lights up and the device stops working Stop Operation After pressing the TIMER button to start running the system will rst run with the default value of low air volume for 2 hours...

Page 12: ...tering by mistake SMART SENSOR LEVEL FAN SPEED Beep x3 TIMER Beep Press again TIMER button Turn o the SMART SENSOR Restart the system 4 If you choose the Boost mode for safety reasons the device will...

Page 13: ...LACE FILTER indicator lights up stop the operation and replace the DI water lter and HEPA lter at the same time Click It must be replaced regularly to maintain the performance of the equipment When th...

Page 14: ...idifying water will be drained immediately after removing the silicone cover Discharge the humidi cation water and the pure water of the EOG Drain humidi cation water Drain pure water 2 3 1 Inside of...

Page 15: ...down the two tabs at the bottom and then remove the bottom cover 2 Separate the terminals of EOG and the main unit 5 Connect the terminals Inside the bottom cover Connection terminal Mark EOG 3 Rotat...

Page 16: ...ons in Section 5 5 If the indicator warning still cannot be removed please contact your service agent Insu cient pure water for the EOG The REFILL TANK indicator lights up The system can work normally...

Page 17: ...ns for use care or maintenance Removal alteration or defacing of the BES a xed serial number and other labels Mechanical damage Use of uids other than clean potable water This warranty is conditional...

Page 18: ...Memo...

Page 19: ......

Page 20: ...www besgroups com info besgroups com BES Group Biotek Environmental Science Ltd...

Reviews: