BioSure PROFESSIONAL EOS7190-P Owner'S Manual Download Page 14

7-

.

MAINTENANCE - 

Draining of humidified water and pure water

Use a cloth dipped in neutral detergent or water to clean the main device, the top air outlet and 

the sides, and then wipe it with a soft dry cloth. Do not use alcohol or thinner.

■ Main Device  Body

■ The air outlet can be disassembled

When cleaning the machine by draining 

humidified water and pure water, be sure to 

stop the operation and disconnect the power.

TIMER

2sec.

Stop 

operating

1.

Stop the operation of the 

equipment and remove the 

humidification water tank. 

Press down the two tabs at 

the bottom, and then remove 

the bottom cover.

4.

Reinstall the bottom cover:

Hook the bottom cover hook to

the main device, then close the two

 tabs and replace the bottom cover. 

3.

Remove the cover to 

drain water.

 

The pure water will be 

discharged immediately 

after removing the cap. 

Please prepare a container

 in advance.

2.

Be sure to remove the 

humidification water tank 

before draining water. Remove 

the silicone cover. Please 

prepare a container in advance. 

The humidifying water will be 

drained immediately after 

removing the silicone cover.

■ Discharge the humidification water and the pure water 

     of the EOG

■ Drain 

     humidification water

■ Drain 

     pure water

2

3

1

Inside of the bottom

※ The discharge points of pure water and humidified water are different, please refer to the figure below when you discharge the operation.

If the main device is turned upside down, 

it may leak water and cause malfunctions.

The lower 

left corner of the 

inner side of the 

back cover

保護ピン

WATER STOPPER

OPENING

1

2

3

Protection of the EOG after draining the pure water

After the pure water is drained,  remove the back cover 

of the main device.

Remove the black plug at the bottom left of the back cover of 

the main device, and use a dropper to inject about 20ml of pure water.
Insert the water shutoff valve.

3.

Replace the black plug, and then replace the back cover.

1.

2.

During transportation, long-term non-use and replacement of the EOG, the humidification 

water and the pure water used by the EOG must be drained.

※ During transportation, long-term non-use and replacement of the electrolytic ozone generator, the humidifica-

tion water and the pure water used by the electrolytic ozone generator must be drained.

13

Summary of Contents for PROFESSIONAL EOS7190-P

Page 1: ...es 5 Preparation Before Use 6 How to Use 7 Maintenance 8 Troubleshooting 9 Speci cations Warranty Description P2 P3 P5 P6 P7 P8 P8 P9 P10 P11 P12 P14 P15 P1 P16 Table of Contents Space Sanitizer Syste...

Page 2: ...EOS7190 P V2 1 EN...

Page 3: ...rying to repair or install 3 The labor costs derived from the normal maintenance calibration or general adjustment speci ed in this manual 4 Maintenance or damage caused by alteration abuse re ood or...

Page 4: ...cause personal injury 2 or property damage 3 if not avoided CAUTION indicates a dangerous situation that may cause personal injury 2 or property damage 3 if not avoided Do not use this product in plac...

Page 5: ...product The input power of the power adapter of this product is AC100 240V Do not use loose sockets Otherwise it may cause re electric shock or short circuit Do not use a damaged power cord or power...

Page 6: ...e do not use electrical electronic contact cleaners in addition to damaging to the appearance these chemicals may also melt the parts Do not rinse the main device with water If the main unit is dirty...

Page 7: ...REFILLING SMART SENSOR 12 9 11 10 1 3 4 5 6 7 2 8 FAN SPEED HUMIDIFIER GENERATOR TIMER LEVEL Mode Humidi cation Start Stop Timing Air Volume Water Replenishment Captions 4 1 Fault indicator 2 Standby...

Page 8: ...g to the Food and Drug Administration FDA According the Occupational Safety and Health Administration OSHA the concentration standard for continuous exposure to ozone is limited to exposure for 8 hour...

Page 9: ...sing please hang the product on the wall or place it on a rm and at table or shelf When ozone is generated the blue operation indicator on the top of the unit will be lit This light cannot be turned o...

Page 10: ...Water shut o valve Plug 6 Press the GENERATOR button to start the water pump The device will beep to start replenishing pure water At this time the REFILLING indicator will light up 7 After the water...

Page 11: ...he STANDBY indicator lights up and the device stops working Stop Operation After pressing the TIMER button to start running the system will rst run with the default value of low air volume for 2 hours...

Page 12: ...tering by mistake SMART SENSOR LEVEL FAN SPEED Beep x3 TIMER Beep Press again TIMER button Turn o the SMART SENSOR Restart the system 4 If you choose the Boost mode for safety reasons the device will...

Page 13: ...LACE FILTER indicator lights up stop the operation and replace the DI water lter and HEPA lter at the same time Click It must be replaced regularly to maintain the performance of the equipment When th...

Page 14: ...idifying water will be drained immediately after removing the silicone cover Discharge the humidi cation water and the pure water of the EOG Drain humidi cation water Drain pure water 2 3 1 Inside of...

Page 15: ...down the two tabs at the bottom and then remove the bottom cover 2 Separate the terminals of EOG and the main unit 5 Connect the terminals Inside the bottom cover Connection terminal Mark EOG 3 Rotat...

Page 16: ...ons in Section 5 5 If the indicator warning still cannot be removed please contact your service agent Insu cient pure water for the EOG The REFILL TANK indicator lights up The system can work normally...

Page 17: ...ns for use care or maintenance Removal alteration or defacing of the BES a xed serial number and other labels Mechanical damage Use of uids other than clean potable water This warranty is conditional...

Page 18: ...Memo...

Page 19: ......

Page 20: ...www besgroups com info besgroups com BES Group Biotek Environmental Science Ltd...

Reviews: