2.  Safety precautions 

 

Caution!

  

Make sure you have fully read and understood the present  Manual 
before using the equipment. Please pay special attention to sections 
marked by this symbol. 

 

Attention! Magnetism!

 Effects of a strong magnetic field on the biological systems 

have to be taken in to account. Magnetic fields can affect heart pace-
makers, data carriers, etc.  

GENERAL SAFETY 

 

The protection provided can be ineffective if the operation of the appliance does not 
comply with the manufacturer's requirements. 

 

Save the unit from shocks and falling. 

 

Store and transport the unit at ambient temperatures between -

20°C and +60°C and 

maximum relative humidity of 80%. 

 

After transportation or storage and before connecting it to the electric circuit, keep the 
unit under room temperature for 2-3 hrs.  

 

Before using any cleaning or decontamination methods except those recommended 
by the manufacturer, check with the manufacturer that the proposed method will not 
damage the equipment. 

 

Do not make modifications in design of the unit.  

ELECTRICAL SAFETY 

 

Connect only to the mains with voltage corresponding to that on the serial number 
label.  

 

Use only the external power supply provided with this product. 

 

Ensure that the power plug is easily accessible during use. 

 

Do not plug the unit into an ungrounded power socket, and do not use an ungrounded 
extension lead.  

 

Disconnect the unit from the mains before moving. 

 

If liquid penetrates into the unit, disconnect it from the mains and have it checked by 
a repair and maintenance technician. 

 

Do not operate the unit in premises where condensation can form. Operating condi-
tions of the unit are defined in the 

Specifications

 section. 

DURING OPERATION 

 

Do not start operation at maximum speed. 

 

Do not operate the unit in environments with aggressive or explosive chemical mix-
tures. Please contact manufacturer for possible operation of the unit in specific at-
mospheres. 

 

Do not operate the unit if it is faulty or has been installed incorrectly. 

 

Do not use outside laboratory rooms. 

BIOLOGICAL SAFETY 

 

The user is responsible to carry out appropriate decontamination if hazardous mate-
rial spills on or penetrates into the equipment. 

 

 

Summary of Contents for MMS-3000

Page 1: ......

Page 2: ...2...

Page 3: ...ting started 6 5 Operation 7 6 Specifications 8 7 Ordering information 9 8 Care and maintenance 9 9 Warranty 10 10 EU Declaration of conformity 11 1 About this edition of user instructions The manual...

Page 4: ...t make modifications in design of the unit ELECTRICAL SAFETY Connect only to the mains with voltage corresponding to that on the serial number label Use only the external power supply provided with th...

Page 5: ...c ele ments may not provide appropriate operation MMS 3000 is equipped with an attachable stand that allows inserting different sen sors temperature pH etc inside the liquid Application fields Chemist...

Page 6: ...e SR 1 attachable stand 1 pce Magnetic stirring element1 1 pce External power supply 1 pce Operating manual declaration of conformity 1 copy 4 3 Setup Place the unit on horizontal even working surface...

Page 7: ...maximum efficient speed is shown in Table 1 for different stirring element lengths and mixing volumes Beyond these numbers mixing might be unstable Note In the model MMS 3000 if the stirring element...

Page 8: ...nsions 110x110 mm 160 mm Working surface material Stainless steel SR 1 detachable stand size 8x320 mm Maximum length of magnetic stirring element 50 mm 70 mm Maximum stirred liquid viscosity Up to 117...

Page 9: ...tand for MMS 3000 BS 010302 AK Magnetic stirring element Cylindrical shape 6x25 mm and PTFE encapsulated BS 010302 S12 8 Care and maintenance 8 1 If the unit requires maintenance disconnect the unit f...

Page 10: ...in the claim form visit Technical support page on our website at link below 9 5 Extended warranty For MS 3000 MMS 3000 the Basic Plus class models extended warranty is a paid service Contact your loca...

Page 11: ...N 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements General requirements LVS EN 61010 1 2011 Safety requirements for electrical equipment for measurement co...

Page 12: ...Biosan SIA Ratsupites 7 build 2 Riga LV 1067 Latvia Phone 371 67426137 Fax 371 67428101 http www biosan lv Edition 2 3 01 October 2018...

Reviews: