background image

NOTE THAT THE 10cm SPACINGS SHOWN ABOVE ARE FROM THE EDGES OF THE PODS, NOT 
THE CENTRE OF THE PODS.

6

pH BOSS INSTALLATION

pH BOSS INSTALLATION

READ THE DO’S AND DON’TS AND TAKE THE TIME TO INSTALL CORRECTLY.

The pH BOSS can be installed onto a new pool or an 
existing pool with minimal pool preparation. Ensure 
that the pool is correctly balanced, in particular the 
Total Alkalinity.

1.  Installing  your  pH  BOSS  takes  around  30 

minutes.

NOTE:

 Turn off all valves prior to fitting the T-piece 

(avoid  leaks),  and  turn  them  back  on  again  before 
switching pool pump back on.

2.  Alternatively engage a competent person to do 

the job.

3.  If installing it yourself you will need :

!

PVC pressure glue and primer.

!

A fine tooth saw.

4.  The  Probe/Injection  Tee  must  be  fitted  on  the 

pipe that sends water back to the pool after it has 
been filtered (the “Return Line”).

!

If a Bionizer and/or Eco-Oxidizer is installed, fit 

the pH BOSS tee BEFORE the Eco-Oxidizer and 
Bionizer Ionizing Pods.

!

If a Salt Chlorinator is installed, fit the pH BOSS 

tee BEFORE the Salt Chlorinator cell. The acid 
will  help  to  keep  the  expensive  Chlorinator 
cells clean.

!

If a liquid Chlorine injection system is fitted, 

install the tee BEFORE the Chlorine injection 
point. The acid will help prevent the Chlorine 
injector becoming clogged with calcium.

TEE PIECE INSTALLATION

1.  For 50mm (2") pipe, cut out a 6cm (2.5") section 

of  pipe  sufficient  for  the  Probe/Injection  Tee 
piece. For 40mm (1.5") pipe, where the reducing 
bushes will be used, cut out a 7cm (2.75") section 
of pipe. 

2.  If the Tee piece diameter is larger than the pipe 

then use the 50mm to 40mm reducing bushes 
provided  by  glueing  them  in  place  in  the  Tee 
piece  before  fitting.  The  pipe  should  now  fit 
snugly into the Tee piece.

3. 

Be  sure  to  install  the  Tee  piece  in  the  correct 
direction of the water flow, as per the arrow on 
the Tee.

 

The Tee piece should be installed so that the pH 

O

Probe is within 30  of vertical. (See next page)

Filter

For sand filters,

glass or silica sand

media provides

optimum results.

Filter

Pressure

Pool

Pump

Oxidizing

Pod

pH Tee

Ionizing

Pod

10cm

min

10cm

min

If a heater is installed, 
then fit the pH Tee 
AFTER the heater.

FLOW  DIRECTION

Summary of Contents for PH BOSS

Page 1: ...TM INSTRUCTION BOOK Automatic Pool pH Control System Please read before you call us for advice Version 1 51d 07 Nov 2017 bionizer com au bionizer com DOWN UP AUTO OFF CANCEL PROGRAM SET TM...

Page 2: ...PUMP HOSE INSTALLATION 8 TEE PIECE HOSE INSTALLATION 9 DRUM WEIGHT HOSE INSTALLATION 9 pH PROBE INSTALLATION 9 PROGRAMMING YOUR pH BOSS 10 AUTO OFF KEY 10 DOSE SETTING 10 MANUAL DOSE 11 CHANGING THE p...

Page 3: ...uted acid every weekortwo So the pH BOSS saves you time frustration AND money Before installing the pH BOSS the pool water should be correctly balanced particularly total alkalinity The pH BOSS can be...

Page 4: ...grammingmenus Presstoscrollthroughthefiveusersettingmenus Presstosavechangeswhenadjustingsettings OK pHreadingiscorrect asperSetPointsetting Add pHreadingisaboveSetPoint pH BOSS dosingpumpwillrun whil...

Page 5: ...e pH BOSS from a genuine Bionizer power adaptor An incorrect adaptor could damage the pH BOSS and will void your warranty 1 WARNING alwaysusedilutedacidat1partacid to4ormorepartswaterwithpH BOSS 2 ALW...

Page 6: ...installed fitthepH BOSS tee BEFORE the Salt Chlorinator cell The acid will help to keep the expensive Chlorinator cellsclean If a liquid Chlorine injection system is fitted install the tee BEFORE the...

Page 7: ...mvertical DO NOT FIT THE TEE TO A VERTICAL PIPE AS THIS WILL MAKE THE pH PROBE HORIZONTAL WHICH WILL RENDER THE pH PROBE INOPERABLE Correctly Installed Tee Incorrectly Installed Tee Do not mount on ve...

Page 8: ...easily Fix the control box in position usingscrewsateachcornerofthebox NOTE Make sure that the pH BOSS is positioned near enough to a power outlet and to the T piece and acid drum to allow the power c...

Page 9: ...to the Tee piece thread Tighten firmly by hand DO NOT OVER TIGHTEN DO NOT USE A TOOL 3 After the pH Probe is installed in the Tee piece connect plug on the pH Probe cable into the probe socket on the...

Page 10: ...terto1partacid page5 For pools with a wet edge and balance tank use a settingof1lowerthanlistedforthepoolsize If the pH BOSS does not keep up with acid demand and the Alarm sounds increase the dose se...

Page 11: ...x Re calibratethepHProbe Seepage12 Problem pHProbeisbrokenorfaulty Fix If re calibration is not possible then replacethepHProbe Seepage9 A replacement pH Probe can be ordered by telephone or online at...

Page 12: ...ationjar seepicture ontheright Fill the Buffer Jar to the 250mL mark with distilled water Filtered tap water canalsobeused Replace both the seal and thelid thenshakewellfor 1 minute to ensure that t h...

Page 13: ...topH BOSS whendone Re connect the pool pump to the Bionizer power outlet or the power output to which it was connectedbeforestartingthisprocedure Switchyourpoolequipmentbackon If using a Bionizer ensu...

Page 14: ...he pump rotor a little and place the squeeze tube between the pump body and the two rollers Push the squeeze tube and rotor into the pump body Ensure that the inlet and outlet are seated in theguideso...

Page 15: ...er Faulty AC DC poweradaptor Replacepoweradaptor PleasecontactyourdistributororBionizer FaultypH BOSS mainunit ReturntoBionizerforrepair DoseSettingissettoohigh ReducetheDoseSettingbyonelevelandchecki...

Page 16: ...dale Rd Suite 410 Scottsdale AZ 85254 USA Phone 1 480 696 2387 Toll Free 1 855 8 IONIZE Email relax bionizer com Web bionizer com Bioniser Pty Ltd 1 173 Bradman Ave Maroochydore QLD 4558 Australia Pho...

Reviews: