background image

10 EN

1. 

Automatic start-up

The BG-Counter has no on/off switch or other buttons.
It automatically starts when connected to 12 V power.  

2. 

Battery check

After the counter is connected to power, there will be from 1 
to 4 beeps, depending on battery voltage.  

• 

4 beeps mean the battery is sufficiently charged

• 

If only 1-3 beeps are heard, this means the battery is low 

and needs charging, and counting function, fan, and CO

2

 

will be off until the voltage increases to >11.8V

• 

If there is no beep at all, see  chapter Troubleshooting / 

Trap does not start up

3. 

Cellular connection check

Following the battery check, the device proceeds to check 
the strength of the cellular connection.  This usually takes 
less than 30 seconds, but may take several minutes, for ex-
ample, if the counter has been moved to a new location with 

a different cellular provider.

At the end of the check, the counter indicates signal strength 
as follows:

•  1-5 long beeps: corresponding to 1-5 bars of signal
•  2 short beeps: no signal, no cellular connection possible

Operating the BG-Counter

If no cellular connection is available, the counter can still be 

operated.  Data will be stored internally, and transmitted the 
next time a connection is available.

4. 

Fan and CO

2

 flow check

After powering up, the fan and CO

2

 valve are switched on 

until the next round 15-minute interval (for example, if pow-
ered up at 16:03 until 16:15).  This provides time for the ope-

rator to confirm that the BG-Pro 12 V fan is, indeed, working, 

and the CO

2

 flow is on.

Confirm fan operation visually by looking into the trap fun

-

nel, or by holding a piece of tissue paper above the funnel.

By default, the CO

2

 flow is adjusted to 50 g/h. The CO

2

 dosing 

valve is located inside the counter housing.  It briefly turns 
on and off every 4 seconds.

Check for the presence of CO

2

 flow as follows:

•  CO

2

 tank valve open

•  audible click from the valve
•  hiss from the CO

2

 release port

5. 

Counter check

If desired, the function of the counter can be verified at this 

time by throwing a small object (for example, a small piece of 
paper) into the trap funnel.  A short beep is heard, indicating 
the counter has registered the object.

The  first  connection  to  the  Cloud  (http://www.bg-counter.
com) takes place at the first round 15 minutes after the coun

-

ter is started (for example, 16:15).
When connecting to the cloud, results are uploaded, and the 

schedule defined on the web site is downloaded and acti

-

vated.

First Cloud Connection

Reset

The BG-Counter is reset every time the power is disconnected and re-connected, and the start-up sequence commences as 
described above.

Depending on the schedule, fan, CO

2

 and/or counting 

function may be turned off at this time.
If this is a new counter, the first connection also auto-registers 

the counter on the website.

Maintenance

Check the BG-Counter and trap bi-weekly or once a month for functionality, remove everything that deters mosquitoes from 
entering the trap such as spider webs, leaves and any dirt.

Summary of Contents for BG-Counter

Page 1: ...Updates for the manual can be found on the website www bg counter com Status July 2020 BG CounterTM Instruction Manual...

Page 2: ...o Power 3 Options Determination of Counting Accuracy Operating the BG Counter First Cloud Connection Reset Maintenance BG Counter Webseite Description Registration at live bg counter com Dashboard Mai...

Page 3: ...he BG Pro with a spe cial 12 V fan or a BG Sentinel trap that remove the insects after they are sucked through to avoid multiple counts of the same insect To ensure accurate counts the trap must not a...

Page 4: ...djustable regulator 1 9 Battery adapter cable 1 10 AC power cord with transformer 1 11 BG Counter fan 3 blade 12 V 2 Solar system 2 1 Solar panel with connectors 2 2 Solar controller with connectors 2...

Page 5: ...until it fits tight F2 Then follow assembly instructions for the BG Pro See manual at www biogents com but do not place the fun nel into the opening on top of the cover F3 The BG Counter will be place...

Page 6: ...and also fix them with nuts F5 3 Set up the BG Pro in the stand Insert an enclosed screw through one of the holes on the central upper bracket of the BG Pro Continue to insert the screw through one of...

Page 7: ...on about this topic see chapter De termination of Counting Accuracy 5 Fix the antenna on the BG Counter Place the BG Coun ter on a flat surface with the antenna connector facing up see Fig F10 Screw o...

Page 8: ...k and make sure it is tight by using a wrench or pliers F14 2 Connect the free end of the CO2 tubing to the regulator F15 unscrew the nut on the outlet thread the end of the CO2 tube through the nut i...

Page 9: ...ottom of the trap However a catch bag can be installed when the BG Counter runs only for a few hours in order to check if the number of counted mosquitoes by the BG Counter corresponds with the actual...

Page 10: ...16 15 This provides time for the ope rator to confirm that the BG Pro 12 V fan is indeed working and the CO2 flow is on Confirm fan operation visually by looking into the trap fun nel or by holding a...

Page 11: ...ter enter your e mail address re enter your e mail address to make sure it s correct enter the serial number of the counter IMEI located on a sticker on the bottom of the counter select from the left...

Page 12: ...g indicate low fan current 5 or low and high supply voltage 6 More information on the dashboard warnings can be found on page 19 in the Troubleshooting section The traps are listed below the map in a...

Page 13: ...the map or in the list below the map In Your Traps main menu left side click on a trap name In Trap Management main menu left side click on a trap name or click on View In the field Trap Day 7 you ca...

Page 14: ...be assigned and click on Users In the Assign Trap to User screen select an operator or guest from the drop down list Click Assign Second possibility Click on Users Find the operator or guest to whom y...

Page 15: ...th exact trap location down to the nearest bush perhaps it is possi ble to use Google Maps to set the exact location of the trap Click on the pencil icon next to Trap Location 11 Now an arrow is shown...

Page 16: ...nter to attract mos quitoes while at the same time repelling other insects This field cannot be edited Data connection Determines how often the counter will try to connect to the website and transmit...

Page 17: ...all on at the same time However if for example a catch bag is installed and the catch is to be retained for coll ection leave the fan on continuously Normally the schedule is set to repeat daily howev...

Page 18: ...esented for 15 minute intervals All times are local time at the last known location of the trap Chart settings In Chart Settings you can select for display Insect Types Mosquitoes Large Objects Small...

Page 19: ...o low Solution Recharge battery or replace with full battery SOS beep during start up Symptom 3 short 3 long 3 short beeps Cause SD card failure Solution Contact support Checking cellular connectivity...