| instructions for use, maintenance and installation |
version 1.0 July 2017
19
The combustion chamber must be cleaned after each used pellet container, vacuumed and/or
emptied of all impurities remaining after the pellets have burned.
Never put pellets which have not burned back in the pellet container or ash box.
6.2.
CONTROL AND PARTS REQUIRING MAINTENANCE
CHECK THE FOLLOWING ITEM AND MAKE SURE THAT THE PELLET BOILER IS OPERATING PROPERLY.
THIS WILL INCREASE ITS EFFICIENCY AND THE EMITTED HEAT INTO THE SYSTEM WILL ALSO INCREASE:
Ensure that the pellet boiler and ashes in it are cool!
•
For perfect cleaning, vacuum ashes from beneath the combustion container and from
combustion chamber every week or at each 200 kg pellet container used (whichever comes
sooner). Use a broom or a brush to clean firebox walls.
•
Clean the fan for extraction of smoke gases by removing fan protection and cleaning fan
blades with a broom or a brush.
GENERAL BOILER CLEANING AFTER THE END OF SEASON OR BEFORE THE START OF SEASON:
Ensure that the pellet boiler and ashes in it are cool!
Disconnect power supply!
•
At the end of heating season, disconnect the boiler from electrical network. It is very
important to clean and inspect the boiler, as described in the instructions.
•
Door seal, fitted with high-temperature resistant fitting material, can detach after prolonged
use. To reattach it, apply high-temperature fitting material on the back of the seal. This
ensures hermetic sealing of firebox doors.
FLUE CONNECTION – CHIMNEY (must be cleaned at the end of each season):
Ensure that the pellet boiler and ashes in it are cool!
•
Flue duct, chimney and chimney cover must be inspected and cleaned every year. Contact
your chimney sweep for professional service.