maximum length: 30 mm,
moisture content: up to 10 %,
combustion value: minimum 16,9 MJ/kg or 4,7 kWh/kg,
ash content: below 0,7 %
•
DO NOT use the boiler as an incinerator;
•
Always ensure maximum safety.
6.
INSTRUCTIONS FOR SAFE IGNITION AND CLEANING OF
BOILER
NEVER use fuel oil, lamp oil or any other oil or any other flammable liquid to ignite the pellet boiler.
Store all such liquids far away from the pellet boiler during operation.
Ensure that the pellet boiler is positioned properly and that it does not move.
Ensure that you have closed the firebox properly, and that it is closed during operation of the pellet
boiler.
Vacuum ashes only when the pellet boiler is cool.
Do not use abrasive products to clean the pellet boiler.
6.1.
REGULAR MAINTENANCE AND CLEANING OF BOILER
Use of vacuum cleaner with separator will make cleaning ashes from the boiler easier.
Before starting any kind of maintenance, also cleaning, heed to the following safety precautions:
•
Shut off the pellet boiler before performing any kind of work
•
Before performing any kind of work on the boiler, make sure that the ashes in the boiler are
cool
Vacuum ashes from the combustion at least once every ten days or at each used pellet container
(only when the boiler is cool) (
figure 10
).
Vacuum and carefully clean the combustion container at least once every ten days or at each used
pellet container (only when the boiler is cool) (
figure 10
).
Once a month, remove the front door at the bottom of the exchanger on the right side of the boiler
and vacuum the inside (
figure 10
).
Always make sure that the pellet boiler and ashes in it are cool.
This is the combustion container for burning pellets (
figure 9
).
We recommend inspecting and cleaning ashes from the bottom
of combustion chamber upon each cleaning. When you place
the combustion container back in its place, make sure that it is
set correctly: it must be pushed towards the back wall all the
way. Only then you can be sure that the boiler will function
properly.
Figure 9