Bio Smart Technologies BioSmart BIO-1500PA Owner'S Manual Download Page 23

Page 22 

Frequently Asked Questions 

©2011 BioSmart Technologies 

Q. What will the BioSmart Air Filtration system remove from the air?  

The BioSmart® Air Filtration system in the BioSmart® Far Infrared Heater will kill 
any biologically active contaminates that are present in the air including bacteria, 
virus, mold and mildew.  

Additionally, the most lethal contaminates in indoor air include the volatile 
organic compounds that irritate the lung lining making an individual more 
susceptible to the bacteria and virus that are in the air. Without removing these, 
an air filtration system has only done half its job.  

The BioSmart® Air Filtration system in the BioSmart® Far Infrared Heater contains 
an interactive TIO2 panel that reacts with UV light inside the unit. The interaction 
of these two components breaks down volatile organic compounds. The 
ionization of these compounds assists the gas-absorption membrane in the filter 
cartridge to absorb these contaminates as they are broken down by the TIOS and 
the Ultraviolet light.  

Once absorbed, these contaminates are held in the filter cartridge which should 
be replaced at the beginning of each winter season before first-use of the heater.  

To re-order a new gas-absorption filter cartridge, refer to the back of the Owner's 
Manual for further directions.  

Q. How long will the BioSmart® gas filtration cartridge last?  

Usually about one winter heating season. 

Q. Can I use multiple heaters in an area? 

Depending on the size of the area, you may wish to use multiple heaters. Many 
heaters may be used. Your heater is rated at 12.5 amps so each heater must plug 
into an independent 15 amp, or greater, circuit. 

Q. How does the BioSmart® Far Infrared Heater save me money? 

The patented quartz heating elements in the BioSmart produce infrared heat 
waves which heat objects in the room quicker than conventional radiant heat 
waves. Using this type of heat can save up to 50% on your heating bill.  

Summary of Contents for BioSmart BIO-1500PA

Page 1: ...lines Operating Instructions Warranty Servicing BioSmart Far Infrared Heaters by BioSmart Technologies Therapeutic infrared heating systems for a green healthy environment BioSmart Technologies BioSma...

Page 2: ...Customer Warranty Service 800 595 9605 Page 1 BioSmart BIO 1500PA BioSmart BIO 1500WA Tuscan Walnut Cabinet...

Page 3: ...ng Instructions Turning Power On Off Operating the UV Air Filtration System Setting the Temperature Switching Between Fahrenheit Celsius Setting the Timer Calibrating the Internal Thermometer Frequent...

Page 4: ...erator interactive TIO2 surface coating for VOC break down UV emitter double thickness gas absorption membrane consisting of activated carbon and a proprietary blend of absorption materials for maximu...

Page 5: ...conventional electric furnace baseboard systems And with current fuel prices the BioSmart Far Infrared Heater will save you even more money than if you were using heating oil or gas heat That means dr...

Page 6: ...energy to keep you warm and cozy BioSmart far infrared heating systems are the ultimate in green technology engineering exceptionally economical extremely quiet they produce comfortable healthy therap...

Page 7: ...gh the various rooms of a home or office Eliminating the ductwork also eliminates the bacteria dust pollen and mold that accumulates in a conventional air conditioning and heat duct system Energy Savi...

Page 8: ...r comparable portable heaters Accurate Temperature Regulation BioSmart portable heaters utilize state of the art electronics and internal electronic thermostats for pin point one degree accuracy That...

Page 9: ...Infrared Heater with BioSmart Air Filtration There are no imitations or substitutes in the market place with the technology or the features offered in the BioSmart Far Infrared Heater It s the techno...

Page 10: ...Features Functions Front of Heater Back of Heater Handle Electrostatic Filter Intake Cord Wrap Caster Wheels Cabinet Front Grill Exhaust Control Panel LED Display Temp Timer DOWN UP TEMPERATURE TIME P...

Page 11: ...s runners or similar coverings Arrange cord away from traffic area and where it will not be tripped over DO NOT insert or allow foreign objects to enter any ventilation or exhaust opening as this may...

Page 12: ...rt automatically Unpacking Your New BioSmart Heater Heater Care Storage General Maintenance and Cabinet Care Clean the filter often to provide for maximum performance When necessary wipe the cabinet c...

Page 13: ...s F feel as though it were 72 degrees F This is due to the heat mixing with humidity evenly for head to toe comfort When the heater is placed in an isolated area i e basement or recreation area any ex...

Page 14: ...MP light will turn off and the temperature is now set Setting the Timer This feature allows you to set a future time for the heater to turn itself on For example if you set the time for 1 hour the hea...

Page 15: ...rotecting the unit and preventing waste by cycling the remaining heat into the room DO NOT unplug the heater until the sound of the fan has stopped Doing so may cause damage to the unit 2 When the hea...

Page 16: ...wer Off 1 Press the POWER button located on the left side of the Control Panel DO NOT UNPLUG the heater read further instructions 2 The sound of the heater fan will continue until the heat has been co...

Page 17: ...f the control panel will indicate that just the heater is operating You can choose to operate just the air purification year round without the heater on by pressing the ENTER button and the appropriat...

Page 18: ...ll illuminate and the temperature display will flash 2 Use the UP and DOWN buttons to select the temperature 3 Press Enter 4 The SET TEMP light will turn off and the temperature is now set Detailed Op...

Page 19: ...g 0 minutes have been set and the DELAY START indicator will illuminate 3 Press the UP or DOWN button to select desired number of minutes up to 59 minutes that you would like the heater to wait to tur...

Page 20: ...ws 1 Turn the heater on 2 Determine base line room temperature in the heater by pressing up and down at the same time The room temperature detected by the heater thermostat will be displayed on the sc...

Page 21: ...e setting displayed on the heater screen will now be measured against the new thermostat setting you have programmed into the heater This entire procedure can be followed skipping step 1 and using the...

Page 22: ...ovation has been incorporated in order to insure long life and dependability Using the heater in a damp or moist area such as a bathroom pool room or sauna room is effective but not recommended for th...

Page 23: ...ompounds assists the gas absorption membrane in the filter cartridge to absorb these contaminates as they are broken down by the TIOS and the Ultraviolet light Once absorbed these contaminates are hel...

Page 24: ...ar air intake for any objects that could obstruct airflow If the heater s airflow is still diminished or has stopped please call Customer Support This is a normal function of the heater DO NOT unplug...

Page 25: ...or detailed instructions on calibrating your heater s thermostat Test the outlet to make sure there is power available and then check the heater display for the flashing TIME DELAY light Press the POW...

Page 26: ...Listed Approvals CTUV US International UL Equivalent Remote Control Credit card type large button surface Cord Storage Yes Pre Filter Life time electrostatic Germicidal Ultraviolet Emitter 254nm TIO2...

Page 27: ...tart Function Up to 24 hours Safety Cut Off Yes Listed Approvals CTUV US International UL Equivalent Remote Control Credit card type large button surface Cord Storage Yes Pre Filter Life time electros...

Page 28: ...2 13 Copper Baffle 14 Heat Blanket Support 15 Infrared Bulb x4 16 UV Bulb 17 Ionizer 18 Cross Flow Fan 19 Rear Sheet Metal Panel 20 Rear Plastic Cover 21 Power Cord Release 22 Electrostatic Filter 23...

Page 29: ...frared Bulb x4 16 UV Bulb 17 Ionizer 18 Cross Flow Fan 19 Rear Sheet Metal Panel 20 Rear Plastic Cover 21 Power Cord Release 22 Electrostatic Filter 23 UV and Ionizer switch 24 Temp Sensor Cover 25 To...

Page 30: ...Customer Warranty Service 800 595 9605 Page 29 BioSmart Heater Schematic...

Page 31: ...PRESSLY LIMITED TO THE DURATION OF THE WARRANTY SET FORTH ABOVE Some jurisdictions do not allow limitations on the length of the implied warranty so the above limitation may not apply to you IN NO EVE...

Page 32: ...nologies Customer Warranty Service 800 595 9605 18324 Cook Road Suite 1 Yelm Washington 98597 BioSmart Technologies North American Distribution and Sales BioSmart Far Infrared Heaters Green Technology...

Reviews: