The following precautions should be observed when installing and operating a Roto-Bin-Dicator PRO device:

•  The installation and wiring of this product must comply with all national, federal, state, municipal and 

local codes that apply.

•  Handle carefully to prevent damage.
•  Do not allow moisture to enter the electronics enclosure. Conduit should slope downward from the 

housing. Install drip loops (or drain fitting) and seal conduit with silicone rubber product.

•  For horizontally mounted units, the conduit openings must face downward.

The unit must be located at the position where level indication is desired. The unit may be mounted through the 
top or side wall of the vessel. To ensure reliable operation, observe the following guidelines when choosing the 
mounting location.

•  DO NOT mount the Roto-Bin-Dicator PRO in an area where the paddle or shaft can contact the vessel.
•  DO NOT mount the Roto-Bin-Dicator PRO where the paddle or shaft are directly in the flow of material. 

The material should be able to flow on to and away from the paddle. If necessary, use a baffle to protect 
the paddle and shaft from falling material (ie. avalanche, mass flow and in-coming flow stream). The 
baffle should be placed 6 to 12 inches above the paddle, distance depend on paddle size.

WARNING:  FOR PRODUCTS MARKED AS TYPE 4X, USE TYPE 4X HUB FITTING; FOR IP66 USE IP66 
HUB FITTING.

WARNING: IN ORDER TO MAINTAIN SAFE OPERATION IN HAZARDOUS LOCATIONS, THE 
INTEGRITY OF THE ALUMINUM CASTING AND THE EPDM SEALS MUST BE MAINTAINED. THE 
USER/INSTALLER MUST AVOID INSTALLATIONS WHERE AGGRESSIVE SUBSTANCES MAY BE 
PRESENT AND COULD AFFECT THE PERFORMANCE OF THESE MATERIALS. CARE MUST BE 
EXCERCISED WHEN REMOVING AND REPLACING THE COVER, SO NO MARRING, SCRATCHING 
OR DAMAGE OCCURS TO THE FLANGES.

CAUTION:  WHEN MOUNTING UNITS, NEVER ADJUST THE ORIENTATION BY TURNING THE HOUSING. 
USE 2-1/4 IN. WRENCH FOR PROCESS FITTING UNITS, OTHERWISE A STRAP WRENCH SHOULD BE 
USED TO TIGHTEN INTO PLACE.

WARNING:  FOR UNITS INSTALLED IN HAZAROUS LOCATIONS, TO REDUCE THE RISK OF IGNITION OF 
HAZARDOUS ATMOSPHERES, CONDUIT RUNS MUST HAVE A SEALING FITTING CONNECTING WITHIN 
18  IN. OF THE ENCLOSURE.

WARNING:  REMOVE POWER FROM THE UNIT BEFORE INSTALLING, REMOVING, OR MAKING 
ADJUSTMENTS.

StockCheck.com

Summary of Contents for Roto-Bin-Dicator

Page 1: ...IOMLAR180212 Rev E Roto Bin Dicator Single Double Switch Models Installation Operation Manual S t o c k C h e c k c o m...

Page 2: ...S t o c k C h e c k c o m...

Page 3: ...zed Personnel Use Misuse III PRODUCT DESCRIPTION 3 Technical Specifications Approvals Ratings IV MECHANICAL INSTALLATION 4 Mounting Location Mounting Surface Preparation Mounting on Side of Bin Mounti...

Page 4: ...OR PROCEDURES WHICH IF NOT FOLLOWED COULD RESULT IN SERIOUS INJURY RISK OF ELECTRICAL SHOCK CAUTION IDENTIFIES CONDITIONS OR PROCEDURES WHICH IF NOT FOLLOWED COULD RESULT IN SERIOUS DAMAGE OR FAILURE...

Page 5: ...not be disposed of in a municipal collection site If you do not have the means to dispose of properly please contact the manufacturer for return and disposal instructions or options STORAGE If the Ro...

Page 6: ...f accessory equipment not recommended by the manufacturer or modification of this device is explicitly forbidden All servicing of this equipment must be performed by qualified service personnel only T...

Page 7: ...achined shaft with two shielded ball bearings Shaft Seal Teflon Viton Lipseal rated 1 2 micron 30 psi 2 1 kg cm2 400 F 204 C Housing and Cover Type 4X IP66 polyester coated aluminum casting Mounting P...

Page 8: ...ould be able to flow on to and away from the paddle If necessary use a baffle to protect the paddle and shaft from falling material ie avalanche mass flow and in coming flow stream The baffle should b...

Page 9: ...at washer customer supplied is recommended between mounting plate and fastening hardware Mounting Plate Gasket Diagram Mounting top of bin 1 Assemble gasket between the mounting plate and the bin 2 Fl...

Page 10: ...d current required see specifications Do not allow moisture to enter the electronics enclosure Conduit should slope downward from the housing Install drip loops and seal conduit with silicone rubber p...

Page 11: ...izes must be selected such that it can safely carry the sum total of all circuits maximum amperage wiring 1 Connect the power source for the motor to the terminal block Continuous power is essential T...

Page 12: ...le Shaft 400 F 204 C Max Temp PADDLES All are stainless steel except model H 373 PART NUMBER MODEL DESCRIPTION LAR110310 H 370 4 Vane 11 2 x 5 Diameter with Pins LAR110360 H 371 4 Vane 2 x 7 Diameter...

Page 13: ...1025 H 10C Micro Switch SP DT with Barrier LAR111026 H 10E Double Micro Switch SP DT with Barrier Nut and Screw LAR120050 H 3 Switch Bracket LAR120070 Housing Cover General Purpose Stainless Steel LAR...

Page 14: ...bly Instead replace the lower housing assembly which includes all of the parts listed below DETAIL Number PART Number DESCRIPTION QTY Required 1 LAR130330 H 12 Bearing 2 2 LAR131250 Spring Washer 2 3...

Page 15: ...__________________________________________________________ ____________________________________________________________________________________________________ ________________________________________...

Page 16: ...oulevard Spartanburg SC 29306 Tel 800 778 9242 Fax 864 574 8063 sales bindicator com www bindicator com 2014 All rights reserved All data subject to change without notice LAR180212 Rev E S t o c k C h...

Reviews: