KBF-S (E6) 08/2018
page 9/88
Figure 4: Type plate (example KBF-S 240 optional chamber 9120-0366)
Indications of the type plate (example)
Information
BINDER
Manufacturer: BINDER GmbH
KBF-S 240
Model designation
Constant climate chamber
Device name
Serial No.
00000000000000
Serial no. of the chamber
Built
2018
Year of construction
Nominal temperature
70 °C / 158 °F
Nominal temperature
IP protection
20
IP type of protection acc. to standard EN 60529
Temp. safety device
DIN 12880
Temperature safety device acc. to standard DIN
12880:2007
Class
3.1
Class of temperature safety device
Art. No.
9020-0366
Art. no. of the chamber
Project No.
---
Optional: Special application acc. to project no.
1,40 kW
Nominal power
8,5 A
Nominal current
200-230 V / 50 Hz
Nominal voltage range +/-10%
at the indicated power frequency
200-230 V / 60 Hz
1 N ~
Current type
Max. operating pressure 15 bar
Max operating pressure in the refrigerating system
(15 bar /
218 PSI)
R 134A - 0,27 kg
Refrigerant type and filling weight
With option internal socket:
Nominal power: 0,90 kW
With option internal socket: increased total nominal
power
Contains fluorinated greenhouse gases covered by the Kyoto Protocol
Symbol on the type plate
Information
CE conformity marking
Electrical and electronic equipment manufactured / placed on the market
in the EU after 13 August 2005 and be disposed of in separate collection
according to Directive 2012/19/EU on waste electrical and electronic
equipment (WEEE).
GS mark of conformity of the “Deutsche Gesetzliche Unfallversicherung
e.V. (DGUV), Prüf- und Zertifizierungsstelle Nahrungsmittel und
Verpackung im DGUV Test“ (German Social Accident Insurance
(DGUV), Testing and Certification Body for Foodstuffs and Packaging
Industry in DGUV Test).
Not valid for UL chambers.
Nominal temp.
IP protection
Safety device
Class
Art. No.
Project No.
Built
70 °C
158 °F
20
DIN 12880
3.1
9120-0366
2018
1,40 kW / 8,5 A
200-230 V / 50 Hz
200-230 V / 60 Hz
1 N ~
Max. operating pressure 15 bar
R 134A – 0,27 kg
Contains fluorinated
greenhouse gases covered
by the Kyoto Protocol
With option internal socket:
Nominal power: 1,90 kW
CONSTANT CLIMATE CHAMBER
BINDER GmbH
Im Mittleren Ösch 5
78532 Tuttlingen / Germany
www.binder-world.com
KBF-S
240
E6
Serial No. 00000000000000
Made in Germany
Summary of Contents for KBF-S 240
Page 75: ...KBF S E6 08 2018 page 75 88 24 7 Dimensions Dimensions size 240...
Page 76: ...KBF S E6 08 2018 page 76 88 Dimensions size 720...
Page 78: ...KBF S E6 08 2018 page 78 88...
Page 79: ...KBF S E6 08 2018 page 79 88...
Page 81: ...KBF S E6 08 2018 page 81 88...
Page 82: ...KBF S E6 08 2018 page 82 88 26 Product registration...
Page 89: ......