25/40
Wooden ceiling
Make sure the surface has been fireproofed,
and that the Mounting Bracket is secured to
beams, or joists.
Turn off the service power line using the circuit
breaker.
3)
Using the Mounting Bracket (1) as a guide,
mark the points where the holes for the 4
self-tapping screws will be drilled.
4)
Remove the Mounting Bracket (1), drill the
4 holes (diam, 3mm), and install the bracket
to the ceiling with the 4 self-tapping screws.
The screws must be tightened fully and the
plate securely fastened to prevent the fan
from oscillating.
Concrete ceiling
Turn off the service power line using its circuit
breaker.
3)
Using the mounting bracket (1) as a guide,
mark the diametrically opposite points
where the holes for the 2 expansion plugs
will be drilled.
4)
Remove the mounting bracket (1), drill the 2
holes (diam.8) and insert the 2 expansion
plugs: use the nuts and insert the flat and
elastic washers for fixing. The nuts must be
tightened fully and the plate securely
fastened to prevent the fan from oscillating.
Remove the cotter
pin and pin from the
rod.
Unscrew the two
safety fixing
screws from the
rod holder.
Slide the support
downwards from
the rod
Remove the pin from the
rod.
Summary of Contents for KBS-6006