Quick Start Manual Rev 1.33
003X-608-133
Page
7
6. Connections
6.1. Cable Connections
•
All cable connections are made to the rear of the instrument
using pluggable screw terminals.
6.2. DC Power (DC PWR + , DC PWR –)
•
The DC supply need not be regulated, provided that it is free
of excessive electrical noise and sudden transients.
•
The instrument can be operated from a high quality plug-
pack as long as there is sufficient capacity to drive both it
and the load cells.
•
If an optional battery pack is fitted, then the supplied
charging system must be used.
6.3. Load Cell Connection
The instrument may be connected for either 4-wire or 6-wire
operation. For more information, refer to
BUILD:CABLE
setting page 19.