Quick Start Manual Rev 1.31
003X-608-133
Page 21
GROUP
(GRP)
ITEM
(ITM)
SELECT
(SEL)
EDIT
(EDT)
Underline = Defaults
OK
CAL
(ctd)
ED.LIN
⊗
(K304 only)
Edit Linearisation Points
Set between zero and full
scale
L1. - - -
Select Linearisation
point 1 to 10 (
L1, L2, L3, L4,
L5, L6, L7, L8, L9, L10
).
(Approx. % of full scale)
<SEL>
to step through list of points.
<OK>
to change selected point or
<ITM>
to exit.
After
<OK>
current weight displays.
Add test weight.
<OK>
to enter corrected weight.
<SEL>
changes position,
<EDT>
changes digit.
<OK>
starts routine (
L.in P
displays).
<ITM>
key to exit,
<OK>
to repeat routine.
CLR.LIN
⊗
(K304 only)
Clear Linearisation
Points
L1. - - -
Select Linearisation
point 1 to 10 (
L1, L2, L3, L4,
L5, L6, L7, L8, L9, L10
)
<SEL>
to step through list of points.
<OK>
to select point to clear or
<ITM>
to exit.
After
<OK>
press
<ITM>
to choose
Cont. Y
(Yes) or
Cont. N
(No).
<ITM>
to return to
CLR.LIN
.
DIR.ZER
⊗
Direct Zero Calibration
(Current weight displays)
<OK>
key to start. Current weight displays.
<OK>
to enter direct zero setting (in mV/V).
<SEL>
changes position,
<EDT>
changes digit.
<OK>
key to store new zero calibration.
<ITM>
to exit or
<OK>
to repeat operation.