Quick Start Manual Rev 1.33
003X-608-133
Page
27
8. Error Messages
8.1. Weighing Errors
•
Check Setup = This item can be checked on site by service
personnel
Error
Description
Resolution
(U - - - - -) The weight is below the
minimum allowable weight
reading.
Increase the weight or
decrease the minimum
allowable weight
reading.
(O - - - - -) The weight is above the
maximum allowable weight
reading.
Warning - overloading
may damage mechanical
scale elements.
Check the condition of
load cell connections.
Check for damaged load
cell.
(ZERO)
(ERROR)
The weight reading is
beyond the limit set for
Zero operation. The
operation of the
<ZERO>
key is limited in the setup
during installation. The
indicator cannot be Zeroed
at this weight.
Increase the Zero Range
(Z.RANGE) or use the
<TARE>
key instead.
(STABLE)
(ERROR)
Scale motion has
prevented a
<ZERO>
,
<TARE>
or
<PRINT>
operation from occurring
on command.
Try the operation again
once the scale is stable.