BIL-JAX 3632T
32
ERROR MESSAGE
DEFINITION OF ERROR
COMMENTS
045 OPEN CIRCUIT TURNTABLE
CW
A load of less than 70mA detected in rotate CW
circuit on power-up.
Check for faulty rotate CW
solenoid coil/wiring.
046 SHORTED CIRCUIT
TURNTABLE CW
Excessive load detected in rotate CW circuit on
power-up.
Check for faulty rotate CW
solenoid coil/wiring.
047 OPEN CIRCUIT TURNTABLE
CCW
A load of less than 70mA detected in rotate CCW
circuit on power-up.
Check for faulty rotate CCW
solenoid coil/wiring.
048 SHORTED CIRCUIT
TURNTABLE CCW
Excessive load detected in rotate CCW circuit on
power-up.
Check for faulty rotate CCW
solenoid coil/wiring.
049 OPEN CIRCUIT OUTRIGGER
RETRACT
A load of less than 70mA detected in outrigger
retract circuit on power-up.
Check for faulty outrigger retract
solenoid coil/wiring.
050 SHORTED CIRCUIT
OUTRIGGER RETRACT
Excessive load was detected when Outrigger
Retract circuit was energized.
Check for faulty outrigger retract
solenoid coil/wiring.
051 OPEN CIRCUIT OUTRIGGER
EXTEND
A load of less than 70mA detected in outrigger
retract circuit on power-up.
Check for faulty outrigger extend
solenoid coil/wiring.
052 SHORTED CIRCUIT
OUTRIGGER EXTEND
Excessive load was detected in outrigger extend
circuit on power-up.
Check for faulty outrigger extend
solenoid coil/wiring.
053 OPEN CIRCUIT
LF OUTRIGGER
A load of less than 70mA detected in left front
outrigger circuit on power-up.
Check for faulty solenoid
coil/wiring at outrigger.
054 SHORTED CIRCUIT
LF OUTRIGGER
Excessive load was detected in left front
outrigger circuit on power-up.
Check for faulty solenoid
coil/wiring at outrigger.
055 OPEN CIRCUIT
RF OUTRIGGER
A load of less than 70mA detected in right front
outrigger circuit on power-up.
Check for faulty solenoid
coil/wiring at outrigger.
056 SHORTED CIRCUIT
RF OUTRIGGER
Excessive load detected in right front outrigger
circuit on power-up.
Check for faulty solenoid
coil/wiring at outrigger.
057 OPEN CIRCUIT
LR OUTRIGGER
A load of less than 70mA detected in left rear
outrigger circuit on power-up.
Check for faulty solenoid
coil/wiring at outrigger.
058 SHORTED CIRCUIT
LR OUTRIGGER
Excessive load detected in left rear outrigger
circuit on power-up.
Check for faulty solenoid
coil/wiring at outrigger.
059 OPEN CIRCUIT
RR OUTRIGGER
A load of less than 70mA detected in right rear
outrigger circuit on power-up.
Check for faulty solenoid
coil/wiring at outrigger.
060 SHORTED CIRCUIT
RR OUTRIGGER
Excessive load detected in right rear outrigger
circuit on power-up.
Check for faulty solenoid
coil/wiring at outrigger.
069 OPEN CIRCUIT
PROPORTIONAL
A load of less than 70mA detected in proportional
valve circuit on power-up.
Check for faulty solenoid
coil/wiring at proportional valve.
070 SHORTED CIRCUIT
PROPORTIONAL
Excessive load detected in proportional valve
circuit on power-up.
Check for faulty solenoid
coil/wiring at proportional valve.