4 – OPERATOR SERVICE
31
ERROR CODE DEFINITIONS
The DISPLAY PANEL located on the ground control panel indicates the present
operating status of the boom lift. If an error condition is detected by the control
processor during start-up or operation, the appropriate error code will be
displayed on this panel.
Refer to Table 4-2 for a comprehensive list of Error Code Definitions and
solutions.
Table 4-2. Error Code Definitions
ERROR MESSAGE
DEFINITION OF ERROR
COMMENTS
001 MACHINE IS IN DOWN ONLY
MODE
Machine was either never leveled, outriggers not
lowered, or machine went out of level with use.
Retract boom to travel position
and extend outriggers using
AUTO
LEVEL
button.
002 LOSS OF PLATFORM
COMMUNICATION
Ground control lost communication with platform
control.
Check for unplugged or damaged
platform control cable.
005 PLATFORM CONTROL HAS
STUCK KEY
Platform control detected a stuck or pressed key
on power up.
Turn key switch off and on again
without pressing any buttons.
008 GROUND CONTROL HAS
STUCK KEY
Ground control detected a stuck or pressed key
on power up.
Turn key switch off and on again
without pressing any buttons.
009 BOOM UP WITHOUT
OUTRIGGERS ON GROUND
Ground control detected the boom is up and all
outriggers are not on the ground
Retract boom to travel position
and extend outriggers using
AUTO
LEVEL
button.
010 LEVEL SENSOR HAS
ERRATIC OUTPUT
The ground control detected an erratic output
from the level sensor.
Retract and extend outriggers
using
AUTO LEVEL
button.
015 MACHINE IS NOT LEVEL
Machine has gone out of level with use.
Retract and extend outriggers
using
AUTO LEVEL
.
016 LIFT
BOOM
A boom rotate, extend, or retract function
requested with boom down.
Raise boom from travel position.
017 STOW BOOM
An outrigger function requested with boom up.
Retract and lower boom to travel
position.
021 OPEN CIRCUIT PRIMARY UP A load of less than 70mA detected in primary up
circuit on power-up.
Check for faulty boom up
solenoid coil and wiring.
022 SHORTED CIRCUIT
PRIMARY UP
Excessive load detected in primary up circuit on
power-up.
Check for faulty boom up
solenoid coil and wiring.
033 OPEN CIRCUIT EXTEND
A load of less than 70mA detected in extend
circuit on power-up.
Check for faulty boom extend
solenoid coil/wiring.
034 SHORTED CIRCUIT EXTEND Excessive load detected in extend circuit on
power-up.
Check for faulty boom extend
solenoid coil/wiring.
035 OPEN CIRCUIT RETRACT
A load of less than 70mA detected in retract
circuit on power-up.
Check for faulty boom retract
solenoid coil/wiring.
036 SHORTED CIRCUIT
RETRACT
Excessive load detected in retract circuit on
power-up.
Check for faulty boom retract
solenoid coil/wiring.
037 OPEN CIRCUIT PLATFORM
LEVEL UP
A load of less than 70mA detected in platform
level up circuit on power-up.
Check for faulty level up solenoid
coil/wiring.
038 SHORTED CIRCUIT
PLATFORM LEVEL UP
Excessive load detected in platform level up
circuit on power-up.
Check for faulty level up solenoid
coil/wiring.
039 OPEN CIRCUIT PLATFORM
LEVEL DOWN
A load of less than 70mA detected in platform
level down circuit on power-up.
Check for faulty level down
solenoid coil/wiring.
040 SHORTED CIRCUIT
PLATFORM LEVEL DOWN
Excessive load detected in platform level down
circuit on power-up.
Check for faulty level down
solenoid coil/wiring.