7
BIJUR DELIMON INTERNATIONAL
OPERATORS MANUAL
CLP
36917 r#1
Loading a Cartridge (Initially)
Type A
1. Retract rod of Grease Gun Assy fully. Rod will stay in withdrawn position.
2. Remove protective cap on Inlet end of cartridge and discard carefully.
3. Remove ring tab on outlet end of cartridge and discard carefully.
4. Slide cartridge fully into tube of grease gun assembly.
5. Thread full assembly into baseplate of CLP. Holding the assembly in a dead vertical position,
Carefully
thread full assembly…, to avoid any
risk of cross-threading.
6. With approximately 1/2 turn left, unlatch the lever, allowing the spring loaded follower onto the grease.
Note: It may be necessary to pull gently ion the rod handle to unlatch the lever.
7. Finish threading the assembly fully home. Orientation of grease gun cartridge assembly is not important for the proper function of the
CLP.
8. Push rod handle fully down.
THIS IS CRITICAL AS
failure to do so, may cause the rod to latch while dropping under normal operation, and
this will result in malfunction of the CLP.
Type B
1. Ensure the appropriate thread adaptor is threaded tight to the base of the CLP to provide the necessary seal on the gasket underneath.
Orientation of the thread adaptor after installation is not important.
2. Unscrew outlet cap from Lube Shuttle cartridge and discard cap carefully.
3. Gently apply pressure to the follower cap to bring grease out flush to the head of the cartridge.
4. Invert the cartridge and carefully thread into adaptor of CLP.
5. Continue threading by hand, until significant resistance is met.
Do NOT
use any mechanical tool to further tighten the cartridge. This is not necessary and will damage the cartridge and possibly the
adaptor.
6. Cartridge is now ready for operation.
Type C
1. Ensure the appropriate thread adaptor is threaded tight to the base of the CLP to provide the necessary seal on the gasket underneath.
Orientation of the thread adaptor after installation is not important.
2. Unscrew outlet cap from cartridge and discard cap carefully.
3. Gently apply pressure to the follower cap to bring grease out flush to the head of the cartridge.
4. Invert the cartridge and carefully thread into adaptor of CLP.
5. Continue threading by hand, until significant resistance is met.
Do NOT
use any mechanical tool to further tighten the cartridge. This is not necessary and will damage the cartridge and possibly the
adaptor.
6. Cartridge is now ready for operation.