36917 r#1
Electrical Connections
All wiring labels are adhered to the underside of the motor cover of the CLP. For Options Y & Z, external labels may be found overhead the
connectors. The wiring diagram labels and the external connector labels for all the available options are given in the next section.
The electrical connections will be made, based on the configuration of CLP ordered.
Firstly, Options X, Y or Z will dictate whether you connect via external connectors or simply run cable through external cable glands and into
the pump. The DC supply should be derived from a suitable and safety approved supply.
OPTION
POWER INPUT
CYCLE SWITCH INPUT
X
Wire directly into pump via M18 Cable Glands (Cable
used should be of industrial quality of diameter
6…10mm)
Wire directly into pump via M16 Cable Glands (Cable
used should be of industrial quality of diameter
4…8mm)
Y
Use DIN 43650-A Connector for Power + Fault
Signal. (See Accessories, electrical Cords for
appropriate connecting cable)
Wire directly into pump via M16 Cable Glands (Cable
used should be of industrial quality of diameter
4…8mm)
Z
Use DIN 43650-A Connector for Power + Fault
Signal (See Accessories, electrical Cords for
appropriate connecting cable)
Use M12x1 Connector for Cycle Switch Signal Input
(See Accessories, electrical Cords for appropriate
connecting cable)
Secondly, Options F and G will dictate whether you are simply wiring to an internal terminal strip or to an integrated controller.
OPTION
DESCRIPTION
DETAILS
F
Internal Terminal Strip
14-way specially designed terminal board.
1. Earth + Terminals 1 to 13 clearly marked
2. Terminals 1-3 Connected Internally (+)
3. Terminals 5-7 Connected Internally (-)
4. Terminals 8-13 dedicated to level cycle switch
5. Terminals 9-10 may be connected by re-orientating jumpers
on the board (as shown on the board)
G
Integrated Controller
Microprocessor based controller.
1. 12-way terminal strip on top, clearly marked
2. Terminals 1-2 for incoming power (+ and – respectively)
3. Terminals 3-4 for motor
4. Terminal 5 for Low Level Switch Input
5. Terminal 9 for Cycle Switch Input
6. Terminal 12 for Fault Relay Common
7. Terminal 10 and 11 for N/C and N/O Fault respectively
8. Terminal 7 for +vdc supply to a powered switch
9. Terminal 6,8 for -vdc supply to all switches