5
BIJUR DELIMON INTERNATIONAL
OPERATORS MANUAL
CLP
36917 r#1
Cartridge Types
There are three cartridge options available with the CLP.
Type A –
DIN 1284, 400g
(14 oz. cartridge)
Type B –
Lube Shuttle, 400g
Type C –
Reiner System (Fuchs), 500g
235mm(L) x 53mm(Dia)
248mm(L) x 53mm(Dia) +
Threaded End 11mm(L) x 33mm
(Dia of Thread)
242mm(L) x 61mm(Dia) +
Threaded End 14mm(L) x
19.5mm(Dia of Thread)
Ring Pull on outlet
Threaded Cap on Outlet
Threaded Cap on Outlet
Open Cap on Inlet (to be removed)
Follower Cap on Inlet (remains in cartridge)
Follower Cap on Inlet (remains in cartridge)
The table below summarizes the benefits of each of these cartridges, when used in the CLP and should assist in deciding which type of
cartridge to use for your particular application
.
Type A
Type B
Type C
Global Availability
Yes
Yes in EU, Not so popular in US as yet
Popular in EU. Not in US as yet
In-built Protection of Cartridge
Yes
No
No
Speed of Replacement
Quick (30…40 seconds)
Instant (10 seconds)
Instant (10 seconds)
Effort of replacement
Mechanical Effort-
Required to withdraw rod
Minimal Effort –
Screw-In by hand
Minimal Effort –
Screw-In by hand
Grease Feed
Spring assisted Follower
Atmospheric Pressurised Follower
Atmospheric Pressurised Follower
Installed Height of Unit
390mm
305mm
322mm
Overhead Clearance Necessary
250mm
30mm
30mm
Min Operating Temperature
-20°deg C (grease dependant)
0°deg C (grease dependant)
0°deg C (grease dependant)
Environment
Industrial / Mobile (Robust)
Industrial (Less Robust)
Industrial (less robust)